Home

href="
USERS INFORMATION MANUAL  
M O D E L T S T A T B B P Q 5 0 1  
5 + 2 D A Y P R O G R A M M A B L E  
Heating & Cooling Systems  
D I G I T A L T H E R M O S T A T  
NOTE TO INSTALLER:  
This manual must be left with the equipment user.  
SINGLE STAGE HEAT & COOL  
THERMOSTAT  
Separate programs for  
weekdays & weekends  
Large, easy to read,  
backlit digital display  
Installation Flexibility  
Batteries required for  
4-wire operation  
next  
Tu  
AM  
I2:00  
run  
off  
SET  
prog  
7
2
72  
set  
5
+2 DAY PROGRAMMABLE  
No batteries needed  
for 5-wire operation  
Meets California Title 24 Residential  
href="
Table Of Contents  
SAFETY WARNINGS  
LOCATION OF CONTROLS  
DISPLAY  
2
3
4
NORMAL OPERATION  
Manual Thermostat Operation  
Time Period Operation  
5
6
7
CLOCK SET  
PROGRAMMING Setup  
Overview  
8
Program Setup  
9
ADVANCED SETUP  
BATTERY REPLACEMENT  
WARRANTY  
16  
18  
19  
Bryant Heating & Cooling Systems Patents Pending 4/03  
Page 1  
href="
Safety Warnings  
TSTATBBPQ501  
CAUTION Follow Installation Instructions carefully.  
DISCONNECT POWER TO THE HEATER -  
AIR CONDITIONER BEFORE REMOVING  
THE OLD THERMOSTAT AND INSTALLING WARNING  
THE NEW THERMOSTAT.  
CAUTION  
The 2 Alkaline “AA” batteries must be replaced at least  
every 12 months to assure proper operation.  
The thermostat will display the Low Battery  
code (fig. 1) on the display of the thermostat  
when it is time to replace the batteries. If the  
FIG. 1  
thermostat is connected to 24v power, the  
Batteries may still be installed, but are not required.  
When  
is displayed the batteries must be replaced  
immediately. The manufacturer cannot be liable for  
improper operation of the thermostat if the batteries are  
not immediately replaced.  
The annual battery replacement is especially critical in  
locations subject to freezing temperatures. The  
thermostat will be unable to turn on the Heat if the  
batteries are exhausted.  
This device complies with Part 15 of the FCC rules.  
Operation is subject to the following 2 conditions:  
(
1) This device may not cause harmful interference, and (2)  
This device must accept any interference received, including  
interference that may cause undesired operation.  
Page 2  
href="
Location of Controls  
HEAT/COOL  
INDICATOR  
next  
Tu  
AM  
I2:00  
UP & DOWN  
run  
off  
SET  
prog  
72  
72  
set BUTTONS  
The Heat/Cool  
indicator will only  
energize if the  
thermostat is system  
powered.  
MODE SWITCH  
Heat, Cool or Off  
FAN SWITCH  
On or Auto  
NEXT BUTTON  
For programming  
How to Use: The Next button is used to advance  
from one step to the next in the programming and  
advanced setup screens of the thermostat (pages 8-16).  
It is also used to enter the Advanced Setup screens (page 16).  
PROGRAM SWITCH  
RUN program  
Program OFF  
SET program  
Page 3  
href="
Display  
MTuWThF  
AM  
PM I2:00  
SaSuHeatCool  
Day  
Morning  
Night  
Evening  
SET  
88  
88  
Day of the week. When programming, MTuWThF  
represents the 5 weekdays, SaSu represent the  
weekend days.  
2
Heat and Cool indicators. In normal operation, Heat  
or Cool appears, reflecting the mode switch position.  
Clock Display.  
Time period indicators. These indicate the part of  
the program that is currently active, if the program  
switch is positioned to Run.  
Desired Set temperature indicator.  
Current room temperature indicator.  
Page 4  
href="
Normal Operation  
PROGRAM  
SWITCH  
next  
Tu  
AM  
Heat  
I2:00  
UP & DOWN  
SET  
BUTTONS  
set  
Program  
Switch  
RUN  
72 72  
OFF  
SET  
MODE SWITCH  
Heat, Cool or Off  
FAN SWITCH  
On or Auto  
Manual Operation (program switch OFF)  
Select heat or cool with the mode switch.  
Normally leave the fan switched to auto.  
In fan auto, the fan will turn on only with a heat  
or cool demand. When Fan On is selected, the  
fan will run continuously.  
Adjust the desired set temperature with the  
Up or Down buttons.  
Page 5  
href="
Normal Operation  
PROGRAM  
SWITCH  
next  
Tu  
AM  
Heat  
I2:00  
UP & DOWN  
SET  
BUTTONS  
set  
Program  
Switch  
RUN  
72 72  
OFF  
SET  
MODE SWITCH  
Heat, Cool or Off  
FAN SWITCH  
On or Auto  
Programmed Operation (program switch RUN)  
Select heat or cool with the mode switch.  
Normally leave the fan switched to auto.  
In fan auto, the fan will turn on only with a heat  
or cool demand. When Fan On is selected, the  
fan will run continuously.  
Optionally; adjust the desired set temperature  
for temporary override. The programmed  
settings will restore in the following time period.  
Page 6  
href="
Clock Set  
Program  
RUN  
Slide the program switch to the SET position.  
OFF  
SET  
Setting the time & day are the first 2 steps after  
sliding the program switch to SET.  
PM 6:00  
Use these buttons to  
adjust the current time.  
Pushing and holding the Up or Down buttons will slew the time by  
1
0s of minutes.  
Press the NEXT button for 5 seconds to enter advanced  
setup. (Page16)  
NEXT  
Su  
Use these buttons to  
adjust the current day.  
Page 7  
href="
Time Period Programming  
Overview  
PROGRAM SWITCH  
Slide the program switch to the SET position.  
The blinking icon(s) on the display may be  
Program  
Switch  
RUN  
OFF  
SET  
changed by pressing the Up or Down buttons.  
After the blinking icon is changed how you want  
it, press the Next button.  
The next icon in ‘programming sequence’ will flash.  
It can be modified with the Up & Down buttons.  
Continue the steps above until programming is complete.  
Slide the program switch to RUN and the thermostat  
will now run the time period programming.  
If the program switch is in the OFF position, the thermostat  
will not run the time period program. In this case the  
thermostat will be a manual heat or cool only thermostat.  
Please be certain to program each time period in chronological  
order to ensure proper programmed operation of the  
thermostat. For example, if the Morning Start Time is  
6
:30am, then the Day Start Time MUST be programmed  
for any time AFTER the 6:30am Morning Start Time.  
Page 8  
href="
Time Period Programming  
Weekday Programming  
Program  
Slide the program switch to the SET position. The  
RUN  
OFF  
SET  
1
st 2 steps are clock and day set, see page 7.  
MTuWThF  
AM  
6:00  
Use these buttons to  
Morning  
adjust the start time for  
the morning time period.  
NEXT  
MTuWThF  
AM  
Cool 6:00  
Use these buttons to  
Morning  
adjust the cool setpoint for  
the morning time period.  
SET  
NEXT  
78  
MTuWThF  
Heat  
AM  
6:00  
Use these buttons to  
Morning  
adjust the heat setpoint for  
the morning time period.  
SET  
NEXT  
70  
MTuWThF  
AM  
8:00  
Day  
Use these buttons to  
adjust the start time for  
the day time period.  
NEXT  
Next Page  
Page 9  
href="
Time Period Programming  
Weekday Programming  
MTuWThF  
AM  
Cool 8:00  
Day  
Use these buttons to  
adjust the cool setpoint for  
the day time period.  
NEXT  
NEXT  
NEXT  
NEXT  
SET  
8
5
MTuWThF  
Heat  
AM  
8:00  
Day  
Use these buttons to  
adjust the heat setpoint for  
the day time period.  
SET  
62  
MTuWThF  
PM 6:00  
Use these buttons to  
adjust the start time for  
the evening time period.  
Evening  
MTuWThF  
Cool 6:00  
PM  
Use these buttons to  
Evening  
adjust the cool setpoint for  
the evening time period.  
SET  
78  
Next Page  
Page 10  
href="
Time Period Programming  
Weekday Programming  
MTuWThF  
PM  
6:00  
Heat  
Use these buttons to  
Evening  
adjust the heat setpoint for  
the evening time period.  
NEXT  
NEXT  
NEXT  
NEXT  
SET  
70  
MTuWThF  
PM I0:00  
Use these buttons to  
adjust the start time for  
the night time period.  
Night  
MTuWThF  
Cool I0:00  
PM  
Use these buttons to  
Night  
adjust the cool setpoint for  
the night time period.  
SET  
82  
MTuWThF  
Heat  
PM  
I0:00  
Use these buttons to  
Night  
adjust the heat setpoint for  
the night time period.  
SET  
62  
Next Page  
Page 11  
href="
Time Period Programming  
Weekend Programming  
AM  
SaSu  
6:00  
Use these buttons to  
Morning  
adjust the start time for  
the morning time period.  
NEXT  
NEXT  
NEXT  
AM  
SaSu  
Cool 6:00  
Use these buttons to  
Morning  
adjust the cool setpoint for  
the morning time period.  
SET  
78  
AM  
SaSu Heat  
6:00  
Use these buttons to  
Morning  
adjust the heat setpoint for  
the morning time period.  
SET  
70  
AM  
SaSu  
8:00  
Day  
Use these buttons to  
adjust the start time for  
the day time period.  
NEXT  
Next Page  
Page 12  
href="
Time Period Programming  
Weekend Programming  
AM  
SaSu  
Cool 8:00  
Day  
Use these buttons to  
adjust the cool setpoint for  
the day time period.  
NEXT  
NEXT  
NEXT  
NEXT  
SET  
8
5
AM  
8:00  
SaSu Heat  
Day  
Use these buttons to  
adjust the heat setpoint for  
the day time period.  
SET  
62  
PM 6:00  
SaSu  
Use these buttons to  
adjust the start time for  
the evening time period.  
Evening  
Cool 6:00  
PM  
SaSu  
Use these buttons to  
Evening  
adjust the cool setpoint for  
the evening time period.  
SET  
78  
Next Page  
Page 13  
href="
Time Period Programming  
Weekend Programming  
PM  
6:00  
SaSuHeat  
Use these buttons to  
Evening  
adjust the heat setpoint for  
the evening time period.  
NEXT  
NEXT  
NEXT  
NEXT  
SET  
70  
PM I0:00  
SaSu  
Use these buttons to  
adjust the start time for  
the night time period.  
Night  
Cool I0:00  
PM  
SaSu  
Use these buttons to  
Night  
adjust the cool setpoint for  
the night time period.  
SET  
82  
PM  
I0:00  
SaSuHeat  
Use these buttons to  
Night  
adjust the heat setpoint for  
the night time period.  
SET  
62  
Next Page  
Page 14  
href="
Time Period Programming  
After completion of setting the time period  
programming, you have 2 options:  
1
) Run the time period program by sliding the  
Program Switch to the RUN position.  
Or,  
Program  
Switch  
RUN  
OFF  
SET  
2
) Do not run the time period program. The  
thermostat will operate as a manual  
heat/cool thermostat. Slide the Program  
Switch to OFF in this case.  
Page 15  
href="
Advanced Setup  
This is normally done by the installer at initial installation.  
Enter advanced setup by adjusting the program switch to  
SET. When the clock is flashing, press NEXT for 5 seconds.  
Do not release the button until this screen appears.  
Use these buttons to  
adjust the deadband  
NEXT  
from 1 to 6 degrees.  
I
Use these buttons to  
adjust the cycles/hour  
from 2 to 6.  
d=no limit (zoning)  
NEXT  
d1=d+no compressor  
6
lockout.  
Yes Step only  
appears  
Select YES to have the  
backlight always on, or NO  
to turn off the backlight 8  
seconds after a button press.  
if connect-  
ed to 24  
NEXT  
volt power  
L I  
Use these buttons to select  
thermostat operation in  
degrees C or F.  
F
If degrees C is selected two presses of the Up or Down  
buttons will be required to change the setpoint.  
Adjust the program switch to OFF or RUN to exit  
Advanced Setup.  
Page 16  
href="
Battery Replacement  
To Open The Thermostat  
The top of the thermostat housing has two (2) screw-  
driver slots to assist when seperating.  
SCREWDRIVER  
SLOTS  
To pull the housing apart, insert a small blade screw-  
driver into the slot and rotate 90 . This will release  
the top housing snaps.  
Repeat the procedure in the other screw driver slot.  
Separate the housing halves by pulling the top  
forward until the pins release, and then lift the bottom  
out.  
The batteries must be replaced  
immediately when the thermostat  
displays the Low Battery code (fig.1).  
FIG. 1  
Page 17  
href="
Battery Replacement  
REPLACE WITH ALKALINE BATTERIES AT LEAST ONCE  
EVERY YEAR, OR WHEN THE “LOW BATTERY”  
APPEARS (pages 2,17).  
ICON  
POSITION BATTERIES AS SHOWN  
USE “AA” SIZE  
ALKALINE BATTERIES  
USE “AA” SIZE  
ALKALINE BATTERIES  
IF THE THERMOSTAT IS CONNECTED TO 24V POWER,  
THE BATTERIES MAY STILL BE INSTALLED. INSTALLING  
THE BATTERIES WHEN SYSTEM POWERED (24VAC) WILL  
KEEP THE CLOCK RUNNING IN THE EVENT OF LINE POWER  
INTERRUPTION.  
Page 18  
href="
Warranty  
5
-Year Warranty - This Product is warranted to be free from defects in material and  
workmanship. If it appears within five years from the date of original installation, whether or  
not actual use begins on that date, that the product does meet this warranty, a new or  
remanufactured part, at the manufacturer’s sole option, to replace any defective part will  
be provided without charge for the part itself; PROVIDED the defective part is returned to  
the distributor through a qualified servicing dealer.  
THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing,  
removing, installing, shipping, servicing or handling of either defective parts or replacement  
parts. Such costs may be covered by a separate warranty provided by the installer.  
THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL  
INSTALLATION LOCATION AND BECOMES VOID UPON REINSTALLATION.  
LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED  
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY)  
ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED  
WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW  
LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU.  
THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND  
MANY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR,  
DEALER, OR OTHER PERSON WHATSOEVER.  
ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED  
DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER  
NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE  
REMAINING TIME PERIOD OF THIS WARRANTY.  
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:  
1
2
3
4
5
6
7
8
. Normal maintenance as outlined in the installation and servicing instructions or owners  
manual including filter cleaning and/or replacement and lubrication.  
. Damage or repairs required as a consequence of faulty installation, misapplication,  
abuse, improper servicing, unauthorized alteration or improper operation.  
. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other  
damages due to the inadequacy or interruption of electrical service.  
. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or  
other conditions beyond the control of the Manufacturer.  
. Parts not supplied or designated by the Manufacturer, or damages resulting from their  
use.  
. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and  
Canada.  
. Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever  
including additional or unusual use of supplemental electric heat.  
. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL  
DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion of  
incidental or consequential damages, so the above may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which may  
vary form state to state.  
Page 19  
href="
Programming Worksheet  
see page 8  
DAY  
PERIOD START TIME COOL HEAT  
Morning  
Monday  
Tuesday  
Wednesday  
Thursday  
Friday  
Day  
Evening  
Night  
Morning  
Day  
Evening  
Night  
Saturday  
Sunday  
Please be certain to program each time period in  
chronological order to ensure proper programmed  
operation of the thermostat. For example, if the  
Morning Start Time is 6:30am, then the Day Start  
Time MUST be programmed for any time AFTER the  
6
:30am Morning Start Time. Also, if the Day Start time  
is set for 10:30am, then the Evening Start Time MUST  
be programmed for any time AFTER the 10:30am  
Day Start Time. Finally, if the Evening Start Time is  
set for 5:30pm, then the Night Start Time MUST be  
programmed for any time AFTER the 5:30pm Night  
Start Time.  
Printed on recycled paper.  
P/N 88-403 Rev. 2  
Form No. OM17-54  
Catalog No. 13TS-TA62