Home

href="
Operating  
Manual  
TH4110B  
Programmable Thermostat  
href="
Quick Reference Card  
Grasp and pull to see basic  
operating instructions at a glance.  
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage,  
do not operate cooling system when outdoor temperature is below 50°F (10°C).  
Need Help?  
For assistance with this product please visit www.honeywell.com/yourhome  
or call Honeywell Customer Care toll-free at 1-800-468-1502  
Read and save these instructions  
®
U.S. Registered Trademark. Patents pending.  
Copyright © 2005 Honeywell International Inc. All rights reserved.  
href="
PRO TH4110B Programmable Thermostat  
Table of contents  
About your new thermostat  
Appendices  
Thermostat features ........................2  
Programming at a glance ................3  
Quick reference to controls............4  
Quick reference to display..............5  
Battery replacement......................15  
In case of difficulty ......................16  
Customer assistance......................18  
Accessories....................................18  
Limited warranty ..........................19  
Programming & Operation  
Set time and day..............................6  
System switch (Heat/Cool) ............7  
Fan switch (Auto/On) ......................8  
Using program schedules................9  
Program schedule overrides ........12  
Compressor protection ................14  
This thermostat is ready to go!  
Your new thermostat is pre-  
programmed and ready to go.  
See page 3 to check settings.  
CAUTION: EQUIPMENT DAMAGE  
HAZARD. To prevent possible  
compressor damage, do not operate  
cooling system when outdoor  
1
temperature is below 50°F (10°C).  
href="
Operating Manual  
About your new thermostat  
Congratulations on the purchase of your new Honeywell thermostat. It has been  
designed to give you many years of reliable service and easy-to-use, push-button  
climate control.  
Features  
Separately programmable weekday/weekend schedules.  
One-touch temp control overrides program schedule at any time.  
®
EnergyStar compliant to greatly reduce your heating/cooling expenses.  
Large, clear display is easy to read.  
Displays both room temperature and temperature setting.  
Built-in compressor protection.  
2
href="
PRO TH4110B Programmable Thermostat  
This thermostat is ready to go!  
Your new thermostat is pre-programmed and ready to go.All you have to do is set  
the time and day.Then check the settings below and change if needed:  
1
2
3
4
Set time and day (required for proper operation)................................See page 6  
Select system setting (Heat/Cool): Preset to Heat..............To change, see page 7  
Select fan setting (Auto/On): Preset to Auto ......................To change, see page 8  
Program schedules: Preset to energy-saving levels  
while you’re at work or asleep (assumes you  
wake at 6 am, leave at 8 am, return at 6 pm  
and go to bed at 10 pm) ..............................................To change, see pages 9-11  
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time,  
and manually adjust the temperature (see pages 12-13).  
3
href="
Operating Manual  
Quick reference to controls  
Digital display (see page 5) Temperature adjustment (see pages 11-13)  
Set: Press to set time/day/  
schedule  
Hold: Press to override  
programmed temperature control  
Run: Press to resume program  
schedule  
System switch (see page 7)  
Cool: Thermostat controls only  
the cooling system.  
Heat: Thermostat controls only  
the heating system.  
Fan switch (see page 8)  
On: Fan runs continuously.  
Auto: Fan runs only when heating  
or cooling system is on.  
Off: Heating and cooling  
systems are off.  
4
href="
PRO TH4110B Programmable Thermostat  
Quick reference to display screen  
Low battery warning  
see page 15)  
Current day/time (see page 6)  
(
Current inside  
temperature  
Temperature setting  
(see pages 11-13)  
Replace Batt  
Inside  
Set To  
°
°
System status  
Heat On/Cool On  
(If flashing, see page 14)  
7
AM  
5
Current program period  
Wake/Leave/Return/Sleep  
7
5
6:30  
(see pages 10-11)  
Wake  
Cool  
On  
Wed  
5
href="
Operating Manual  
Set the time and day  
Press SET, then adjust time  
Press the SET button, then press  
1
2
or  
to set the clock time.  
Set  
Clock  
Press the SET button, then press  
or  
week.  
to select the day of the  
AM  
:30  
6
3
Press RUN to save & exit.  
Press SET, then select current day  
Note: If the display flashes Set Clock,  
the thermostat will follow your settings  
for the weekday “Wake” time period until  
you reset the time and day.  
Set Day  
Wed  
6
href="
PRO TH4110B Programmable Thermostat  
System switch  
The SYSTEM switch can be set to con-  
trol your heating or cooling system,  
depending on the season.  
Heat: Thermostat controls only  
the heating system.  
Cool: Thermostat controls only  
the cooling system.  
Off: Heating and cooling  
systems are off.  
CAUTION: EQUIPMENT DAMAGE  
HAZARD. To prevent possible  
compressor damage, do not operate  
cooling system when outdoor  
Set SYSTEM switch to control the heating or  
cooling system.  
temperature is below 50°F (10°C).  
7
href="
Operating Manual  
Fan switch  
Set the FAN switch to Auto or On.  
In“Auto”mode (the most commonly  
used setting), the fan runs only  
when the heating or cooling system  
is on.  
If set to“On ,” the fan runs  
continuously. Use this setting for  
improved air circulation, or for  
more efficient air cleaning.  
Set FAN switch to choose whether the fan  
runs continuously or only as needed.  
8
href="
PRO TH4110B Programmable Thermostat  
Save money by setting program schedules  
It’s easy to program your system for maximum energy savings.You can program four  
time periods each day, with different settings for weekdays and weekends.  
WAKE  
Set to the time you awaken and the temperature you want  
during the morning, until you leave for the day.  
6
:00 am  
°
7
8
0
LEAVE  
:00 am  
Set to the time you leave home and the temperature you  
want while you are away (usually an energy-saving level).  
°
6
2
RETURN Set to the time you return home and the temperature you  
6:00 pm  
want during the evening, until bedtime.  
°
7
1
0
SLEEP  
0:00 pm  
Set to the time you go to bed and the temperature you want  
overnight (usually an energy-saving level).  
6
2°  
9
href="
Operating Manual  
®
EnergyStar settings for maximum cost savings  
®
This thermostat is pre-set to use EnergyStar program settings.We recommend  
these settings, since they can reduce your heating/cooling expenses by as much  
as 33%. (See next page to adjust times and temperatures of each time period.)  
Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun)  
Wake  
7
0°  
2°  
0°  
62°  
75°  
83°  
75°  
78°  
70°  
75°  
(
6:00 am)  
Leave  
8:00 am)  
°
°
6
62  
83  
(
[
Or cancel period]  
[Or cancel period]  
Return  
6:00 pm)  
°
°
7
70  
75  
(
[
Or cancel period]  
[Or cancel period]  
Sleep  
10:00 pm)  
62°  
78°  
(
10  
href="
PRO TH4110B Programmable Thermostat  
To adjust program schedules  
Press SET 3 times, then adjust time  
Press SET until Set Schedule is displayed.  
1
2
Set To  
Press  
time (Mon-Fri), then press SET.  
Press or to set the temperature for  
or  
to set your weekday Wake  
Set Schedule  
°
5
Heat  
7
3
4
AM  
6
:30  
this time period, then press SET.  
Wake  
MonTueWedThuFri  
Set time and temperature for the next  
time period (Leave). Repeat steps 2 and 3  
for each weekday time period.  
Press SET to set weekend time periods  
(Sat-Sun), then press RUN to save & exit.  
Press SET, then set desired temperature  
Set To  
5
Set Schedule  
°
5
Heat  
7
AM  
Note: Make sure the thermostat is set to the  
system you want to program (Heat or Cool).  
6
:30  
Wake  
MonTueWedThuFri  
Note: To cancel an unwanted time period (except  
Wake), press and hold  
+ HOLD for 4 seconds  
while in the Set Schedule mode.  
11  
href="
Operating Manual  
Program schedule override (temporary)  
Press to temporarily adjust temperature  
Press  
or  
to immediately adjust the  
Temporary  
temperature.This will temporarily override  
the temperature setting for the current time  
period.  
Set To  
°
7
0
AM  
6
:30  
The new temperature will be maintained  
only until the next programmed time period  
begins (see page 10). For example, if you  
want to turn up the heat early in the morn-  
ing, it will automatically be lowered later,  
when you leave for the day.  
Press to resume program schedule  
Set To  
°
7
5
AM  
6
:30  
To cancel the temporary setting at any time,  
press RUN.  
Note: Make sure the thermostat is set  
to the system you want to control  
(heat or cool).  
12  
href="
PRO TH4110B Programmable Thermostat  
Program schedule override (permanent)  
Press to permanently adjust temperature  
Press HOLD to permanently adjust the  
temperature.This will override the  
Hold  
Set To  
temperature settings for all time periods.  
°
70  
AM  
:30  
The“Hold” feature turns off the program  
schedule and allows you to adjust the  
thermostat manually, as needed.  
6
Press to resume program schedule  
Whatever temperature you set will be  
maintained 24 hours a day, until you  
manually change it, or press RUN to cancel  
“Hold”and resume the program schedule.  
Set To  
°
75  
AM  
:30  
6
Note: Make sure the thermostat is set  
to the system you want to control  
(heat or cool).  
13  
href="
Operating Manual  
Built-in compressor protection  
This feature helps prevent damage to the  
compressor in the air conditioning or heat  
pump system.  
Inside  
Set To  
°
°
7
AM  
5
6:30  
Wed  
5
Cool  
On  
Damage can occur if the compressor is re-  
started too soon after shutdown.This feature  
forces the compressor to wait for a few  
minutes before restarting.  
7
Wake  
During the wait time, the message Cool On  
Message flashes until safe  
restart time has elapsed  
(or Heat On if you have a heat pump) will  
flash on the display.When the safe wait time  
has elapsed, the message stops flashing and  
the compressor turns on.  
14  
href="
PRO TH4110B Programmable Thermostat  
Battery replacement  
Grasp and pull to  
remove thermostat  
Install fresh batteries immediately  
when the REPLACE BATT warning begins  
flashing.The warning flashes about  
two months before the batteries are  
depleted.  
Turn thermostat over,  
insert fresh AA alkaline  
batteries, then reinstall  
thermostat  
Even if the warning does not appear,  
you should replace batteries once a  
year,or before leaving home for more  
than a month.  
If batteries are inserted within 1  
minute,the time and day will not have  
to be reset. All other settings are  
permanently stored in memory,and  
do not require battery power.  
15  
href="
Operating Manual  
In case of difficulty  
If you have difficulty with your thermostat, please try the suggestions below. Most  
problems can be corrected quickly and easily.  
Display is blank  
Make sure fresh AA alkaline batteries are correctly installed (see page 15).  
Heating or  
cooling system  
does not respond  
Set system switch to Heat (see page 7). Make sure the temperature is  
set higher than the Inside temperature.  
Set system switch to Cool (see page 7). Make sure the temperature is  
set lower than the Inside temperature.  
Check circuit breaker and reset if necessary.  
Make sure power switch at heating & cooling system is on.  
Make sure furnace door is closed securely.  
Wait 5 minutes for the system to respond.  
16  
href="
PRO TH4110B Programmable Thermostat  
In case of difficulty  
Temperature  
settings do not  
change  
Make sure heating and cooling temperatures are set to acceptable ranges:  
Heat: 40° to 90°F (4.5° to 32°C).  
Cool: 50° to 99°F (10° to 37°C).  
Cool On” or  
Heat On” is  
Compressor protection feature is engaged. Wait 5 minutes for the system  
to restart safely, without damage to the compressor (see page 14).  
flashing  
Heat On” is  
Set the System switch to Heat, and set the temperature level above the  
current room temperature (see page 7).  
not displayed  
“Cool On” is  
Set the System switch to Cool, and set the temperature level below the  
current room temperature (see page 7).  
not displayed  
To restore  
Energy Star  
default settings  
Follow these steps to restore Energy Star default settings (see page 10):  
®
1
2
3
Press SET 3 times to display “Set Schedule.”  
Press and hold SET and RUN at the same time for 4 seconds.  
Press RUN.  
17  
href="
Operating Manual  
Customer assistance  
Grasp and pull to  
remove thermostat  
For assistance, please visit  
www.honeywell.com/yourhome.  
Or call Honeywell Customer Care  
toll-free at 1-800-468-1502.  
Turn thermostat over  
to find model number  
and date code  
To save time, please note your model  
number and date code before calling.  
Accessories  
For accessories, please call Honeywell  
Customer Care toll-free at  
1-800-468-1502.  
Cover plate................Part No. 50002883-001  
Used to cover marks left by old thermostats.)  
(
18  
href="
PRO TH4110B Programmable Thermostat  
Limited 2-year warranty  
Honeywell warrants this product, excluding battery, to be free from defects in the  
workmanship or materials, under normal use and service, for a period of two (2)  
years from the date of purchase by the consumer. If at any time during the warranty  
period the product is determined to be defective or malfunctions, Honeywell shall  
repair or replace it (at Honeywell's option).  
If the product is defective,  
(i) return it, with a bill of sale or other dated proof of purchase, to the place from  
which you purchased it; or  
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the  
determination whether the product should be returned to the following address:  
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley,  
MN 55422, or whether a replacement product can be sent to you.  
19  
href="
Operating Manual  
Limited 2-year warranty  
This warranty does not cover removal or reinstallation costs.This warranty shall  
not apply if it is shown by Honeywell that the defect or malfunction was caused  
by damage which occurred while the product was in the possession of a  
consumer.  
Honeywell's sole responsibility shall be to repair or replace the product within  
the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR  
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL  
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY  
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.  
Some states do not allow the exclusion or limitation of incidental or consequential  
damages, so this limitation may not apply to you.  
20  
href="
PRO TH4110B Programmable Thermostat  
Limited 2-year warranty  
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON  
THIS PRODUCT.THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING  
THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR  
PURPOSE, IS HEREBY LIMITEDTOTHETWO-YEAR DURATION OFTHIS WARRANTY.  
Some states do not allow limitations on how long an implied warranty lasts, so the  
above limitation may not apply to you.  
This warranty gives you specific legal rights, and you may have other rights which  
vary from state to state.  
If you have any questions concerning this warranty, please write Honeywell  
Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call  
1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/  
Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9.  
21  
href="
Automation and Control Solutions  
Honeywell International Inc.  
985 Douglas Drive North  
Honeywell Limited-Honeywell Limitée  
1
35 Dynamic Drive  
Golden Valley, MN 55422  
Scarborough, Ontario M1V 4Z9  
www.honeywell.com/yourhome  
Printed in U.S.A. on recycled  
paper containing at least 10%  
post-consumer paper fibers.  
® U.S. Registered Trademark.  
© 2005 Honeywell International Inc.  
Patents pending. All rights reserved.  
69-1770 02-2005