Home

href="
Operating  
Manual  
TH8320ZW1000  
Touchscreen Thermostat  
6
9-2485EFS-01  
href="
BE CAREFUL! Never use sharp instruments, such as a  
pencil or pen, to press touchscreen keys. To prevent damage  
to the thermostat, always press keys with your fingertip.  
This thermostat contains a Lithium battery which may  
contain Perchlorate material.  
Perchlorate Material—special handling may apply,  
See www.dtsc.ca.gov/hazardouswaste/perchlorate  
M29343  
Need Help?  
For assistance with this product please visit http://yourhome.honeywell.com  
or call Honeywell Customer Care toll-free at 1-800-468-1502  
Read and save these instructions.  
®
U.S. Registered Trademark.  
US Patent No. 6,574,581, 6,975,958, 7,114,554, 7,346,467, 7,636,604, 7,693,582, 7,788,936, 7,845,576, and other patents pending.  
Copyright © 2011 Honeywell International Inc. All rights reserved.  
href="
TH8320ZW1000  
Table of contents  
About your new thermostat  
Appendices  
In case of difficulty.............................. 18  
Regulatory information ....................... 20  
Limited warranty.................................. 21  
Thermostat features.............................. 2  
Programming at a glance ..................... 3  
Quick reference to controls .................. 4  
Quick reference to status display ........ 5  
Settings  
Clock setting.......................................... 6  
Fan setting............................................. 7  
System setting....................................... 8  
This thermostat is ready to go!  
Your new thermostat is pre-  
programmed and ready to go.  
See page 3 to check settings.  
Programming & Operation  
Screen lock............................................ 9  
Screen cleaning................................... 10  
Battery replacement............................ 11  
Advanced functions ............................ 12  
CAUTION: EQUIPMENT DAMAGE  
HAZARD. To prevent possible  
compressor damage, do not operate  
cooling system when outdoor  
temperature is below 50˚F (10˚C).  
1
69-2485EFS—01  
href="
Operating Manual  
About your new thermostat  
Congratulations! You’ve just purchased the world’s most advanced, easy-to-use  
themostat. It has been designed to give you many years of reliable service and  
touchscreen climate control.  
Features  
One-touch temp control overrides program schedule at any time.  
Precise comfort control keeps temperature within 1°F of the level you set.  
Change/check reminders let you know when to service or replace filters and  
other critical components.  
Large touchscreen display with backlight is easy to read—even in the dark.  
Z-Wave wireless control lets you connect the thermostat to a Z-Wave network.  
6
9-2485EFS—01  
2
href="
TH8320ZW1000  
TA hb ios u tt h ye or um ro ns et aw t ti sh er re ma do ys t tao t go!  
Your new thermostat is pre-programmed and ready to go. Just set the time and day.  
Then check the settings below and change if needed:  
1. Set clock .......................................................................................................See page 6  
2
3
. Select fan setting: Preset to Auto.............................................................See page 7  
. Select system setting: Preset to Heat.....................................................See page 8  
3
69-2485EFS—01  
href="
Operating Manual  
Quick reference to controls  
Press day(s) to set program schedule  
Press to select fan  
Press to adjust  
operation (see page 7)  
temperature settings  
MON  
TUE  
WED  
THU  
FRI  
SAT  
SUN  
Press to select  
system type (see  
page 8)  
Press for more options  
(select models only)  
Press to set program  
schedule  
SUN  
M32520  
Press to override  
program schedule  
Press to set clock  
(see page 6)  
Press to lock keypad for 30  
seconds to clean screen  
(see page 10)  
6
9-2485EFS—01  
4
href="
TH8320ZW1000  
Quick reference to status display  
Current day of week  
Current inside temperature  
Temperature setting  
Fan setting  
Inside  
Set To  
FAN  
Program schedule on  
does not display  
when off)  
7
0
(
AUTO  
75  
:10  
System setting  
Following  
Schedule  
SUN  
SYSTEM  
AM  
Recovery  
8
HEAT  
Current time  
Adaptive Intelligent  
Recovery in effect  
SCHED  
HOLD  
CLOCK SCREEN  
M32521  
Other display messages:  
Cool On: Cooling system is activated  
Heat On: Heating system is activated  
Aux Heat On: Auxiliary heating system is activated  
5
69-2485EFS—01  
href="
Operating Manual  
Clock setting  
Press CLOCK  
To set the current time display, press CLOCK,  
then press s or t to adjust the time. Press  
and hold s or t to advance the time more  
quickly.  
AM  
6
:01  
HOLD  
SCHED  
CLOCK SCREEN MORE  
Press DONE to save & exit (or press CANCEL to  
exit without changing the time).  
M32527  
Adjust time, then press DONE  
Note: The real-time clock should never  
require adjustment since it automatically  
updates for daylight savings time, and  
stores all date/time information.  
FAN  
Inside  
Set To  
AUTO  
70  
7
0
Note: To change the current week day dis-  
play, see page 13.  
WED  
AM  
6
:02  
DONE  
CANCEL  
M32528  
6
9-2485EFS—01  
6
href="
TH8320ZW1000  
Fan setting  
Press FAN to select fan operation, then  
press DONE.  
On: Fan is always on.  
Inside  
Set To  
Auto: Fan runs only when the heating or  
cooling system is on.  
FAN  
7
0 70  
WED  
AUTO  
Circ: Fan runs randomly, about 35% of  
the time, not counting any run time with  
the heating or cooling system.  
Following  
SYSTEM  
Schedule  
AM  
HEAT 6:01  
You can press FAN to override the fan set-  
tings you’ve programmed for different time  
M32529 periods. If you select On or Circ, the setting  
SCHED  
HOLD  
CLOCK SCREEN  
Press FAN  
you select will remain active until you press  
FAN again to select Auto (see page 19 for  
more information).  
Note: If a fan schedule is programmed,  
Auto” will run the fan schedule.  
7
69-2485EFS—01  
href="
Operating Manual  
System setting  
Press the SYSTEM button to select, then press  
DONE.  
Heat: Thermostat controls only the  
heating system.  
Inside  
Set To  
FAN  
AUTO  
SYSTEM  
HEAT  
70 70  
:01  
 Cool: Thermostat controls only the  
cooling system.  
Following  
WED  
Schedule  
Off: Heating and cooling systems are  
AM  
6
off.  
SCHED  
HOLD  
CLOCK SCREEN  
 Auto: Thermostat automatically selects  
heating or cooling depending on the  
indoor temperature.  
M32522  
Press SYSTEM  
Em Heat (only for heat pumps with  
auxiliary heat): Thermostat controls  
Emergency and Auxiliary Heat.  
6
9-2485EFS—01  
8
href="
TH8320ZW1000  
SA cb ro eu et ny ol ou cr knew thermostat  
To prevent tampering, the screen can be par-  
tially or fully locked.  
WED  
SCREEN LOCKED  
FAN  
Inside  
Set To  
When partially locked, the screen displays  
SCREEN LOCKED for several seconds if a  
locked key is pressed. To unlock the screen,  
press any unlocked key while SCREEN LOCKED  
appears on the screen.  
AUTO  
70  
7
0
Following  
Schedule  
SYSTEM  
HEAT  
PM  
6
SCHED  
:00  
HOLD  
When the screen is fully locked, no keys  
function. To lock or unlock the screen, see  
advanced function 0670 on page 17.  
CLOCK SCREEN MORE  
M29357  
See advanced func-  
tion 0670 (page 17) for  
screen lock options  
9
69-2485EFS—01  
href="
Operating Manual  
SA cb ro eu et ny oc ul er a nn ei nw gthermostat  
Press SCREEN  
Press SCREEN to lock the screen for  
cleaning. The screen will remain locked for  
WED  
3
0 seconds so you can clean the screen  
PM  
6
SCHED  
:00  
HOLD  
without changing any settings.  
CLOCK SCREEN USAGE  
After 30 seconds, press DONE to resume  
normal operation, or press SCREEN again if  
you require more time for cleaning.  
M32526  
Screen lock timer (30 seconds)  
Note: Do not spray any liquid directly on the  
thermostat. Spray liquids onto a cloth, then  
use the damp cloth to clean the screen. Use  
water or household glass cleaner. Avoid  
abrasive cleansers.  
M32523  
6
9-2485EFS—01  
1
0
href="
TH8320ZW1000  
Battery replacement  
Remove tab.  
The thermostat is shipped from the  
factory with the coin cell installed.  
To keep the battery from discharg-  
ing during shipment and storage,  
the thermostat is shipped with a  
plastic tab inserted in the battery  
holder. This tab must be removed  
during installation. Simply pull the  
plastic tab out of the battery tray.  
Make sure that the battery tray is  
fully inserted into the thermostat.  
M32429  
1
1
69-2485EFS—01  
href="
Operating Manual  
Advanced functions  
1
. Press SYSTEM.  
2. Press and hold blank center key until the display changes.  
SYSTEM  
AM  
SUN  
6
:01  
HEAT  
DONE  
CANCEL  
M32530  
M32525  
Function  
Setting  
3
4
. Change settings as  
required (see pages  
1
3-17).  
0
120  
20  
DONE  
M32531  
. Press DONE to exit &  
Press s / t to  
Press s / t to  
save changes.  
select function  
change setting  
6
9-2485EFS—01  
1
2
href="
TH8320ZW1000  
Advanced functions  
Year setting (first two digits)  
Function  
120  
Options: 20 = Year 20xx  
1 = Year 21xx  
Press s / t to change the first two digits of the year:  
0
2
Year setting (second two digits)  
0130  
Press s / t to change the last two digits of the year:  
Options: 01 - 99 (i.e., 2001 - 2099)  
Month setting  
0140  
Press s / t to change the current month:  
Options: 1 - 12 (i.e., January - December)  
Date setting  
0150  
Press s / t to change the current date:  
Options: 1 - 31  
Program schedule on/off  
0160  
Press s / t to turn the program schedule on or off:  
Options:  
0
4
Non-programmable  
Programmable  
1
3
69-2485EFS—01  
href="
Operating Manual  
Advanced functions  
Restore Energy Saving Schedule  
Function 0165  
Options:  
0
1
No  
Yes  
Continuous Backlight  
0280  
Options:  
0
1
No  
Yes  
Temperature format (°F/°C)  
0320  
Press s / t to set the temperature display format:  
Options:  
0
1
Fahrenheit  
Celsius  
Daylight savings time on/off  
0330  
The thermostat is pre-programmed to automatically adjust to daylight savings time.  
Press s / t to select an option:  
Options:  
0
1
Off: No adjustment for daylight savings time  
On: Auto-change to daylight savings time (through 2006, and for areas that  
do not use the new 2007 DST calendar)  
6
9-2485EFS—01  
1
4
href="
TH8320ZW1000  
Advanced functions  
Furnace Filter Change Reminder  
Function  
0
500  
Options:  
0
1
2
3
4
5
6
7
8
9
Off  
10-day run time (about 1 month)  
30-day run time (about 3 months)  
60-day run time (about 6 months)  
90-day run time (about 9 months)  
120-day run time (about 1 year)  
180-day run time (about 1.5 years)  
270-day run time (about 2 years)  
365-day run time (about 3 years)  
30 calendar days  
1
1
1
1
1
0 60 calendar days  
1 90 calendar days  
2 120 calendar days  
3 180 calendar days  
4 365 calendar days  
UV Lamp Replacement Reminder  
0
520  
Options:  
0
1
2
Off  
365 days  
730 days  
1
5
69-2485EFS—01  
href="
Operating Manual  
Advanced functions  
Adaptive Intelligent Recovery  
Function 0530  
Options:  
0
1
Off  
On  
Program schedule periods  
0
540  
Options:  
Press s / t to set the number of program periods:  
2
4
Two program periods (Wake, Sleep)  
Four program periods (Wake, Leave, Return, Sleep)  
Heat Energy Saving Setpoint  
0
615  
Options: 40-90° F 65  
.5-32° C 18.5  
4
Cool Energy Saving Setpoint  
0
616  
Options: 50-99° F 78  
0-37° C 25.5  
1
6
9-2485EFS—01  
1
6
href="
TH8320ZW1000  
Advanced functions  
Clock format  
Function  
640  
Options: 12 12-hour clock (i.e., “3:30 pm”)  
4 24-hour clock (i.e., “15:30”)  
Press s / t to set the clock display format:  
0
2
Screen lock  
0
670  
Options:  
Press s / t to choose a screen lock setting (see page 7):  
0
1
2
Screen is unlocked (fully functional)  
All functions locked except temperature controls and CANCEL key  
Screen is fully locked  
Z-Wave InclusionZ-Wave Inclusion  
RF10  
Options:  
0
1
Exclude  
Include  
Share Z-Wave Node Information  
RF20  
Options:  
0
1
Idle  
Send node  
1
7
69-2485EFS—01  
href="
Operating Manual  
In case of difficulty  
If you have difficulty with your thermostat, please try the following suggestions.  
Most problems can be corrected quickly and easily.  
Display is blank  
Check circuit breaker and reset if necessary.  
Make sure power switch at heating & cooling system is on.  
Make sure furnace door is closed securely.  
No response to  
key presses (or