The Unit can be used with most 24 volt gas, oil or electric heating and air  
conditioning systems, single-stage heat pumps or gas millivolt heating  
systems. It cannot be used with 120 volt heating systems or multistage heat  
pumps. Ask your dealer for other LUX thermostats to control those systems.  
INSTALLATION AND OPERATING  
INSTRUCTIONS  
The Unit is programmable. There are four programming periods per day. Each  
period can be programmed separately.  
You can use the built-in time/temperature programs, or alter them to suit  
your schedule. The Unit provides separate programming for every day of the  
week- for both heating and cooling. You can override the programmed tempera-  
tures for as little as one programming period or for an entire vacation.  
In cool weather, when the system switch is set to HEAT, the Unit will maintain  
cooler set back” room temperatures to save energy. It will then change to  
warmer “comfort” settings — all automatically, at specified times during the day.  
In warm weather, when the system switch is set to COOL, the Unit will maintain  
warmer “set back” room temperatures to save energy. It will then change to  
cooler comfort” settings - all automatically, at specified times during the day.  
A large liquid crystal display shows time, day of the week, and room and set  
temperatures. It will remind you when the filter should be changed in your blower  
and track your systems energy usage.  
Temperature swing adjustment lets you fine-tune your system for maximum  
comfort and economy.  
A 4-minute minimum on/off time in COOL prevents your air conditioning  
system from being damaged.  
Two Energizer® or DURACELL® “AA” alkaline batteries (not included) are  
used to retain your time and temperature programs.  
TX9000 SERIES  
SMART TEMP® ELECTRONIC THERMOSTAT  
UP  
DAY  
HEAT  
DOWN  
MO  
UP  
MO  
UP  
DAY  
DAY  
Easy  
as  
HEA  
T
HEA  
T
PM  
DOWN  
DOWN  
S
S
P
ET  
TURDA  
ROGRAM  
S
S
P
ET  
UNDAY  
S
S
P
ET  
TURDA  
ROGRAM  
T  
NDAY  
A
Y
A
Y
RESET  
RESET  
ROGRAM  
FAN  
OGRAM  
FAN  
HEA  
T
HEAT  
AUTO  
AUTO  
S
ET  
WEEKDA  
PROGRAM  
S
ET  
EKDA  
OGRAM  
OFF  
Y
FILTER  
HOLD  
Y
FILTER  
HOLD  
ON  
ON  
COOL  
S
ET  
RUN  
RUN  
NEXT  
NEXT  
DA  
Y
/
TIME  
1500  
P a t e n t s P e n d i n g  
1500  
P a t e n t s P e n d i n g  
S
IMPLIFIED INSTRUCTIONS  
TEMPORARY TEMPERATURE OVERRIDE  
S
IMPLIFIED INSTRUCTIONS  
TEMPORARY TEMPERATURE OVERRIDE  
TO  
S
ET TIME  
&
DA  
Y
Press UP/DOWN to set time.  
TO  
S
ET TIME  
&
DA  
Y
Press UP/DOWN to set time.  
Rotate Dial to SET  
DAY/TIME.  
•Press UP/DOWN to adjust set temperature.  
Rotate Dial to SET  
DAY/TIME.  
•Press UP/DOWN to adjust set temperature.  
TO  
S
ET  
P
ROGRAMS  
• Rotate Dial to SET  
•T  
o clear OVERRIDE press UP/DOWN until  
original set temperature appears or wait for  
TO  
S
ET  
P
ROGRAMS  
• Rotate Dial to SET  
•T  
o clear OVERRIDE press UP/DOWN until  
original set temperature appears or wait for  
Press UP to change  
Press UP to change  
1–2–3  
Installs Easily  
Set Day & Time  
Choose Heat or Cool  
LUX PRODUCTS CORPORATION  
Mt. Laurel, New J ersey 08054 USA  
52002  
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.  
Energizer® is a registered trademark of Eveready Battery Company, Inc.  
DURACELL® is a registered trademark of The Gillette Company, Inc.  
I M P O R T A N T !  
C
A
U
T
I
O
N
Your thermostat is a precision instrument. Please handle it with care.  
Turn off electricity to the appliance before installing or servicing  
thermostat or any part of the system. Do not turn electricity back on  
until work is completed.  
Thank you for your confidence in our product. To obtain the  
best results from your investment, please read these  
READ  
instructions and acquaint yourself with your purchase  
before installing your new thermostat. Then follow the  
installation procedures, one step at a time. This will save  
INSTALLATION  
• Do not short (jumper) across electric terminals at control on furnace or  
air conditioner to test the system. This will damage the thermostat and  
void your warranty.  
• All wiring must conform to local codes and ordinances.  
• This thermostat is designed for use with 24 volt and millivolt systems.  
The thermostat should be limited to a maximum of 1.0 amps; higher  
amperage may cause damage to the thermostat. If you are in doubt,  
call your utility company.  
you time and minimize the chance of damaging the  
thermostat and the systems it controls. These instructions  
may contain information beyond that required for your  
particular installation. Please save for future reference.  
INSTRUCTIONS  
FIRST  
FEATURES  
INSTALLATION  
The Active Program Period  
The Set  
Please read all instructions carefully before beginning installation.  
Temperature  
Liquid Crystal  
Display  
LUX Speed  
Dial®  
C
A U T I O N  
TOOLS REQUIRED  
To avoid electrical shock  
and to prevent damage  
to the furnace, air condi-  
tioner, and thermostat,  
disconnect the power  
supply before beginning  
#1 Phillips screwdriver (small)  
Drill with 3/16-in. (4.8mm) bit  
THERMOSTAT LOCATION  
On replacement installations,  
mount the new thermostat in  
place of the old one unless the  
conditions listed below suggest  
otherwise. On new installations,  
follow the guidelines listed below.  
Thermostat  
Body  
F
OF  
work. This can be done at the  
fuse box, at the circuit breaker, or  
at the appliance.  
System  
Switch  
1. Locate the thermostat on an  
inside wall, about 5 ft. (1.5m)  
above the floor, and in a room that is used often.  
Fan Switch  
2. Do not install it where there are unusual heating conditions, such as: in direct  
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near  
hot water pipes in a wall; near a stove on the other side of a wall.  
3. Do not locate in unusual cooling conditions, such as: on a wall separating an  
unheated room; or in a draft from a stairwell, door, or window.  
PATENT NO. 5,673,850  
SIMPLIFIED INSTRUCTIONS  
TEMPORARY TEMPERATURE OVERRIDE  
•Press UP/DOWN to adjust set temperature.  
To clear OVERRIDE press UP/DOWN until  
original set temperature appears or wait for  
the start tf the next period.  
TO SET TIME & DAY  
TO S