TCONT900AC43UACommunicating,  
Programmable Comfort Control  
OWNER’S GUIDE  
Pub No. 22-5211-02  
69-1817-04  
href="
TABLE OF CONTENTS  
Page  
3
4
Contents  
Features  
Home Screen  
6
Programming Your Heating and Cooling Schedule  
Operating Your Comfort Control  
Cleaning Your Comfort Control Screen  
Reading Your Outdoor Temperature  
Reading Your Inside Humidity Level  
Controlling Your Inside Dehumidification Setting  
Controlling Your Inside Humidification Setting  
Advanced Settings  
User Setup Menu  
Error Codes  
Frequently Asked Questions and Answers  
Limited Five-Year Warranty  
Customer Assistance  
14  
21  
22  
26  
27  
29  
34  
36  
47  
48  
49  
51  
IMPORTANT  
The Comfort Control has a touch screen interface. Touch keys appear, as necessary, to  
complete tasks. Always press the keys with your fingertips. Sharp instruments like a pen or  
pencil point can damage the Comfort Control.  
22-5211-02  
2
69-1817—04  
FEATURES  
Large, Clear Display with Backlighting – current temperature, set temperature and time are  
easy-to-read and all are displayed on the home screen.  
Menu Driven Programming – Guides you through the scheduling process, showing only  
necessary information and choices on each screen.  
Ability to Select Multiple Days – allows you to easily customize the Comfort Control for your  
unique schedule.  
Real-Time Clock – keeps time during power failure; automatically updates for daylight savings.  
Precise Temperature Control (+/- 1°F) (+/- .5°C) – reliable, consistent comfort.  
Multiple HOLD options – allows you to modify schedule indefinitely or for a specific time.  
Change Reminders – reminds you to service or replace the air filters and/or humidifier pad.  
Programmable Fan – increases air quality when combined with a whole-house air cleaner.  
Outdoor Temperature Indication – shows current outdoor temperature on the display to help  
you plan outdoor activities.  
NOTE: The home screen may differ slightly, depending on the heating and/or cooling system you  
have and the Comfort Control settings for your system type.  
22-5211-02  
3
69-1817—04  
href="
HOME SCREEN  
Key Description  
TUE  
FAN  
SELECTS ON/AUTO/CIRC  
UP ARROW  
RAISES TEMPERATURE SETTING  
Inside  
Set To  
AUTO  
SYSTEM  
SELECTS EM. HEAT/HEAT/OFF/COOL/AUTO  
DOWN ARROW  
LOWERS TEMPERATURE SETTING  
Following  
Schedule  
HEAT  
AM  
MORE (SELECT MODELS)  
SHOWS ADDITIONAL SYSTEM  
INFORMATION  
SCHED  
HOLD  
CLOCK SCREEN MORE  
SCHED  
ENTERS SCHEDULING MODE  
SCREEN  
LOCKS OUT THE SCREEN TO ALLOW FOR CLEANING  
CLOCK  
SETS THE TIME FORWARD OR BACK  
HOLD  
SETS A PERMANENT HOLD AND  
ACTIVATES VACATION HOLD  
M19952  
22-5211-02  
4
69-1817—04  
href="
HOME SCREEN  
Display Description  
INSIDE TEMPERATURE  
SHOWS THE CURRENT INSIDE TEMPERATURE  
TUE  
SHOWS CURRENT DAY OF THE WEEK  
SET TO TEMPERATURE  
SHOWS THE CURRENT  
SET TEMPERATURE  
TUE  
FAN  
SHOWS FAN SETTING  
Inside  
Set To  
AUTO  
SYSTEM  
SHOWS CURRENT SYSTEM POSITION  
Following  
Schedule  
FOLLOWING SCHEDULE  
HEAT  
SHOWS THE THERMOSTAT IS  
FOLLOWING THE PROGRAMMED  
SCHEDULE  
AM  
TIME  
DISPLAY CURRENT TIME OF DAY,  
HOLD TIME REMAINING OR NUMBER  
OF VACATION DAYS REMAINING  
SCHED  
HOLD  
CLOCK SCREEN MORE  
M19953  
22-5211-02  
5
69-1817—04  
PROGRAMMING YOUR HEATING AND COOLING SCHEDULE  
Your Comfort Control can control up to four different schedule periods per day:  
Wake – Period when you awaken and want your home at a comfortable temperature.  
Leave – Period when you are away from home and want an energy-saving temperature.  
Return – Period when you return home and want your home back to a comfortable temperature.  
Sleep – Period when you are asleep and want an energy-saving temperature.  
22-5211-02  
69-1817—04  
6
href="
NOTE: Schedule times are in 15-minute intervals.  
Preprogrammed Energy Star Settings  
additional education and resources on programmable Comfort Controls.  
Table 1. Energy Star Default Program Settings.  
Schedule Period  
Time  
Setpoints  
Fan Setting  
Heat  
Cool  
Wake  
Leave  
Return  
Sleep  
6:00 AM  
8:00 AM  
6:00 PM  
10:00 PM  
70°F (21°C)  
62°F (16.5°C)  
70°F (21°C)  
62°F (16.5°C)  
78°F (25.5°C)  
85°F (29.5°C)  
78°F (25.5°C)  
82°F (27.8°C)  
Auto  
Auto  
Auto  
Auto  
22-5211-02  
7
69-1817—04  
href="
FRI  
EDITING SCHEDULE  
FAN  
Inside  
Set  
1. Press Sched key.  
AUTO  
Following  
Schedule  
SYSTEM  
HEAT  
AM  
PM  
SCHED  
HOLD  
CLOCK SCREEN  
M22445  
2. Press Edit key.  
MON  
TUE  
WED  
THU  
FRI  
SA  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
FAN  
Inside  
Set  
HEAT  
AUTO  
Following  
Schedule  
CANCEL  
PERIOD  
SYSTEM  
EM HEAT  
HEAT  
OFF  
COOL  
AM  
PM  
COOL  
AUTO  
SCCHED  
EDIT  
HOLD  
WAKE  
CLOCK SCREEN  
LEAVE RETURN SLEEP CANCEL  
M22553  
DONE  
22-5211-02  
8
69-1817—04  
href="
3. It is OK to pick multiple days. Select any combination of days to edit. These days are sched-  
uled with the same times and temperatures. Check marks appear next to days selected.  
MON  
TUE  
WED  
THU  
FRI  
SAT  
SUN  
OK TO PICK MULTIPLE DAYS  
FAN  
ON  
HEAT  
AUTO  
CIRC  
CANCEL  
PERIOD  
AM  
COOL  
DONE  
WAKE  
LEAVE RETURN SLEEP CANCEL  
M19955  
4. Press Wake key. Once pressed, Wake flashes to show it is selected.  
5. Press Up and Down keys to modify time and heat and cool temperatures from this screen.  
NOTE: The Fan setting can be programmed for On, Auto, or Circ for each period selected. See  
“Fan Schedule” on page 19 for more information.  
22-5211-02  
69-1817—04  
9
href="
6. Press Leave key and repeat step 5.  
7. Press Return key and repeat step 5.  
8. Press Sleep key and repeat step 5.  
9. When complete, press Done key. “Saving Changes” appears on the screen to indicate  
changes are being saved to the day(s) modified.  
MON  
TUE  
WED  
THU  
FRI  
SAVING  
CHANGES  
M19956  
NOTE: To set a Program Schedule for the remaining days of the week, repeat steps 1-9.  
Example: If Mon - Fri was selected first, go back and repeat steps 1-9 for Sat and Sun.  
10. To exit schedule without saving changes, press Cancel key any time.  
22-5211-02  
69-1817—04  
10  
href="
CANCELING A SCHEDULE PERIOD  
NOTE: You may want to cancel a period to match your lifestyle; for example, if someone is always  
home during the day on Tuesday, you can cancel the Leave and Return periods (the Com-  
fort Control would then control to the Wake temperature until the Sleep period).  
1. Press Sched key.  
2. Press Edit key.  
3. Select the Day(s) of the week desired.  
4. Press schedule period you want to cancel (Wake, Leave, Return or Sleep). Once selected, the  
period flashes.  
5. Press Cancel Period key.  
MON  
TUE  
WED  
THU  
FRI  
SAT  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
FAN  
Inside  
Set To  
HEAT  
AUTO  
Following  
Schedule  
CANCEL  
PERIOD  
SYSTEM  
EM HEAT  
HEAT  
OFF  
AM  
PM  
COOL  
COOL  
AUTO  
SCCHED  
HOOLLDD  
WAKE  
CLOCK SCREEN  
LEAVE RETURN SLEEP CANCEL  
DONE  
M22446  
22-5211-02  
11  
69-1817—04  
href="
NOTE: Note that the time, temperature(s) and fan setting disappear. The bar above the selected  
period is removed, indicating the scheduled period was cancelled. To reinstate a schedule  
period, press arrow keys to set desired time and temperatures.  
6. Press Done key.  
MON  
TUE  
WED  
THU  
FRI  
SAT  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
FAN  
Inside  
Set To  
HEAT  
AUTO  
Following  
Schedule  
CANCEL  
PERIOD  
SYSTEM  
EM HEAT  
HEAT  
OFF  
AM  
PM  
COOL  
COOL  
AUTO  
SCCHEDD  
HOOLLDD  
WAKE  
CLOCK SCREEN  
LEAVE RETURN SLEEP CANCEL  
DONE  
M22446  
NOTE: When changing from non-programmable to programmable mode, the screen displays “Per-  
manent Hold” under the time icon. This goes away when the schedule key is hit or the  
schedule menu is entered.  
22-5211-02  
12  
69-1817—04  
href="
SETTING TIME  
1. Press Clock.  
2. Use arrows to set current time.  
TUE  
AM  
PM  
SCCHED  
HOLD  
CLOCK SCREEN  
DONE  
M19958  
3. Press Done key.  
IMPORTANT  
The current day of the week should already be set correctly. If not, see “Advanced Settings”  
on page 34 to set the day.  
22-5211-02  
13  
69-1817—04  
Setting Fan and System Keys  
SETTING FAN KEY  
The Fan key selections vary based on your heating and/or cooling system type.  
On – Fan runs continuously. Use this setting for improved air circulation or for more efficient central  
air cleaning. The Trane Proprietary Humidity Control might disable continuous fan function. See  
“Trane Proprietary Humidity Control” on page 28 for additional information.  
Auto – Fan follows fan program schedule. See “Fan Schedule” on page 19 for more information.  
Circ – Circulation control will provide a variable circulation determined by the Adaptive Intelligent  
Circulation (AIC) algorithm running the fan between 20% and 60% of the time.  
SETTING SYSTEM KEY  
The System key selections vary based on your heating and/or cooling system type.  
Heat – Controls your heating system.  
Off – Both heating and cooling systems are off.  
Cool – Controls your cooling system.  
Auto (when enabled) – Controls both your heating and cooling system based on temperature.  
Em. Heat – Compressor is locked out and auxiliary heat cycles to maintain temperature. (Used only  
for heat pump systems with backup heat)  
22-5211-02  
14  
69-1817—04  
Setting Temperature Overrides  
Your Comfort Control has three temperature override options: Hold Temperature Until, Permanent  
Hold and Vacation Hold.  
HOLD TEMPERATURE UNTIL (TEMPORARY HOLD)  
Holds temperature temporarily until the next scheduled period time or until the time the user sets.  
1. Press Up or Down arrow next to the temperature you want to adjust. “Hold Temperature Until”  
time appears on the screen. The Hold Temperature Until time defaults to the start time of the  
next scheduled period.  
NOTE: The Time Up and Down arrows are shown for approximately seven seconds. Pressing on  
the screen time (where the Hold Temperature Until time is shown) allows the arrows to  
reappear.  
2. Press Up or Down arrow next to the Time key to set desired time for the Comfort Control to  
resume schedule.  
22-5211-02  
15  
69-1817—04  
href="
3. Press the Cancel or Sched key to cancel “Hold Tem-  
TUE  
perature Until” and resume schedule.  
FAN  
Inside  
Set  
NOTE: Once “Hold Temperature Until” time is reached, the  
comfort control shows “Following Schedule” on the  
screen to indicate that “Temporary Hold” has ended.  
AUTO  
SYSTEM  
Hold Temperature  
Until  
HEAT  
PERMANENT HOLD  
Permanent Hold changes the temperature setting until  
Permanent Hold is cancelled.  
PM  
SCHED  
HOLD  
CLOCK SCREEN  
CANCEL  
M19959  
1. Press Hold key. “Permanent Hold” appears on the  
screen.  
2. Press Up or Down arrow next to the temperature you  
want to set during “Hold”.  
3. Press Cancel key to cancel “Permanent Hold” and  
resume the schedule.  
TUE  
FAN  
Inside  
Set To  
AUTO  
SYSTEM  
NOTE: In ISU 0160, when changing from nonprogrammable  
to programmable mode, the screen displays “Per-  
manent Hold” under the time icon. This goes away  
when the schedule key is hit or the schedule menu  
is entered.  
HEAT  
AM  
Permanent  
Hold  
SCHED HOLD  
CLOCK SCREEN  
CANCEL  
M19960  
22-5211-02  
16  
69-1817—04  
VACATION HOLD  
Changes temperature setting for a selected number of days, from 1 to 365 days.  
1. Press the Up and Down arrow keys to set the desired temperature while away on vacation.  
Notice that “Hold Temperature Until” time is shown on the screen. (This is the time the  
Vacation Hold override expires after the number of days ends.)  
2. Press Hold key twice. Screen shows “Hold Temperature Until” one day.  
3. Press Up and Down arrow keys to change the number of Days you desire Comfort Control to  
override the schedule.  
NOTE: Days Up and Down arrows appear for approximately seven seconds. Pressing just below  
Hold Temperature Until on the screen allows the Days Up and Down arrows to reappear.  
NOTE: When the number of days of Vacation Hold expires, the screen shows “Following  
Schedule” to indicate that Vacation Hold has ended.  
22-5211-02  
17  
69-1817—04  
href="
4. To cancel the Vacation Hold override early, press the Cancel key.  
THU  
FAN  
Inside  
Set To  
AUTO  
SYSTEM  
Hold Temperature  
Until  
HEAT  
DAYS  
SCHED  
CLOCK SCREEN  
CANCEL  
M19961  
22-5211-02  
18  
69-1817—04  
href="
Fan Schedule  
Press Fan key while in the Scheduling Screen to program the System Fan. Choices available from  
the Scheduling Screen:  
On – Fan runs continuously. Use this setting for improved air circulation or for more efficient central  
air cleaning.  
Auto – (default position) Fan runs with equipment. Programmable for all schedule periods (Wake,  
Leave, Return and Sleep).  
Circ – Circulation control will provide a variable circulation determined by the Adaptive Intelligent  
Circulation (AIC) algorithm running the fan between 20% and 60% of the time.  
MON  
TUE  
WED  
THU  
FRI  
SAT  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
FAN  
Inside  
Set To  
HEAT  
AUTO  
Following  
Schedule  
CANCEL  
PERIOD  
M  
EAT  
EAT  
OFF  
AM  
PM  
COOL  
COOL  
AUTO  
SCCHEDD  
HOOLLDD  
WAKE  
CLOCK SCREEN  
LEAVE RETURN SLEEP CANCEL  
DONE  
M22447  
22-5211-02  
19  
69-1817—04  
 
href="
Fan Status Displayed on Home Screen  
If the Fan program is scheduled, Auto is shown and any programmable mode that is set; for  
example, if during Wake period, Fan is set to Auto, only Auto is shown in the Fan area. However, if  
during the Wake period, fan is scheduled to On, both Auto and On are shown. Auto indicates fan is  
running its schedule; On indicates Fan schedule is set to On.  
THU  
FAN  
ON  
Inside  
Set  
AUTO  
Following  
Schedule  
SYSTEM  
HEAT  
AM  
SCHED  
HOLD  
CLOCK SCREEN  
M19962  
Manual Override of Fan Schedule  
On – Fan runs continuously. Use this setting for improved air circulation or for more efficient  
central air cleaning. The Trane Proprietary Humidity Control might disable continuous fan function.  
See “Trane Proprietary Humidity Control” on page 28 for additional information.  
Auto – (default position) Fan follows fan program schedule. See “Fan Schedule” on page 19 for  
more information.  
Circ – Circulation control will provide a variable circulation determined by the Adaptive  
Intelligent Circulation (AIC) algorithm running the fan between 20% and 60% of the time.  
22-5211-02  
20  
69-1817—04  
href="
CLEANING YOUR COMFORT CONTROL SCREEN  
The Comfort Control has a touch screen interaction. Follow these steps to clean the screen without  
making comfort control changes:  
1. Press Screen key. Comfort Control locks out touch keys for 30 seconds to allow for cleaning.  
2. Use damp cloth slightly moistened with  
water and mild dishwasher detergent to  
clean thescreen.  
3. Repeat the above steps, as necessary.  
OK TO  
CLEAN  
M19964  
IMPORTANT  
Do NOT spray any type of liquid directly on the Comfort Control itself.  
4. Press the Done key to return to the Home Screen and normal operation.  
22-5211-02  
21  
69-1817—04  
 
href="
READING YOUR OUTDOOR TEMPERATURE  
If the communicating Comfort Control has discovered an outdoor temperature sensor, the comfort  
control displays the outdoor temperature.  
VIEW OUTSIDE TEMPERATURE  
The outside temperature is located in the lower right corner of the Home Screen.  
NOTE: If the communicating Comfort Control is in auto mode, the outdoor temperature can be dis-  
played by pressing the More key.  
MON  
TUE  
WED  
THU  
FRI  
SA  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
CHANGE FILTER UV LAMP HUMIDIFIER PAD  
FAN  
Set  
AUTO  
Heat On  
Following  
Schedule  
SYSTEM  
Outside  
HEAT  
AM  
SCHED  
HOLD  
CLOCK SCREEN MORE  
M19971  
22-5211-02  
22  
69-1817—04  
href="
Reminder Timers  
These reminders notify you when to change your furnace filters, humidifier pad, or other  
accessories. When the time you set expires, the Comfort Control flashes “Change” and then “Filter”  
or “Change” and “Humidifier Pad” until you reset the timer.  
NOTE: See Steps 11 through 13.  
Resetting Expired Timers  
When a Timer expires, a Reset key appears on the Home Screen. Press Reset key to reset the  
Timer. Notice that the “Change” reminder disappears from the Comfort Control screen. If more than  
one Timer expires at the same time, press the Reset key to reset all expired Timers.  
MONN  
TUE  
WED  
THHU  
FRRI  
SA  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
CHANGE FILTER UV LAMP HUMIDIFIER PAD  
FAN  
Inside  
Set To  
AUTO  
Following  
Schedule  
SYSTEM  
HEAT  
PM  
SCHED  
HOLD  
CLOCK SCREEN MORE  
M19975  
22-5211-02  
23  
69-1817—04  
View or Reset Timer Settings Before They Expire  
1. Press More key until the Timer you want to modify appears on the screen.  
2. Press Edit key to change the Timer reload value. Use Up and Down arrow keys to change the  
number of Run Time Days. See Advanced Settings, steps 11 through 13, for approximate  
calendar days.  
3. Press the Done key to go back to viewing the selected timer.  
4. Press Reset key to reset the timer to the timer reload value. (This is the Advanced setting you  
set or the reload value you selected in step 2.)  
5. Press Done or Cancel key to return to the Home Screen.  
Screen Locked  
You can fully or partially lock out the keys on the touch screen interface. See “Advanced Settings” on  
page 34 for information on turning these features on or off. If the Comfort Control shows “Screen  
Locked,” your Comfort Control screen is either fully or partially locked.  
22-5211-02  
24  
69-1817—04  
 
href="
Partially Locked Screen  
When partially locked, the screen indicates Screen Locked for 5 to 7 seconds whenever the user  
attempts to press a key that is locked. Pressing a locked key while Screen Locked is shown flashes  
Screen Locked on the screen. Pressing an unlocked key while Screen Locked is active removes the  
screen lock.  
In this mode, all keys are locked except the Temperature Up and Down arrow keys:  
— User can change temperature up or down but cannot change schedule settings.  
Temporary temperature change lasts until next scheduled period and that time shows onscreen.  
To cancel temperature override and begin following schedule, press Cancel key.  
To unlock screen, see “Advanced Settings” on page 34.  
TU  
SCREEN LOCKED  
FAN  
Inside  
Set  
AUTO  
Following  
Schedule  
SYSTEM  
HEAT  
SCHED HOLD CLOCK SCREE MORE  
M19965  
22-5211-02  
25  
69-1817—04  
href="
Fully Locked Screen  
In this mode, all keys are locked and not functional. To unlock screen, see “Advanced Settings” on  
page 34. The screen continuously displays “Screen Locked”.  
The communicating Comfort Control can sense the humidity level in the home. The humidity level in  
the home is shown in the lower right corner of the Home Screen.  
NOTE: If the communicating Comfort Control is in auto mode, the indoor humidity level can be  
displayed by pressing the More key.  
NOTE: CONTINUOUS fan mode during COOLING  
TUE  
operation may not be appropriate in humid cli-  
mates. The Trane Proprietary Humidity Control  
might disable continuous fan function. See  
“Trane Proprietary Humidity Control” on  
page 28 for additional information. If the indoor  
air exceeds 60% relative humidity or simply  
feels uncomfortably humid, it is recommended  
that the fan only be used in the AUTO mode.  
FAN  
Inside  
Set  
AUTO  
Following  
Schedule  
SYSTEM  
HEAT  
PM  
Humidity  
SCHED  
HOLD  
CLOCK SCREEN MORE  
M19966  
22-5211-02  
69-1817—04  
26  
href="
CONTROLLING YOUR INSIDE DEHUMIDIFICATION SETTING  
If the dehumidification control has been enabled, the communicating Comfort Control will read the  
inside humidity level and set a desired humidity level to help dehumidify the house.  
1. Press the More key until the inside humidity percent and dehumidification setpoint are shown.  
2. Use Up and Down arrow keys, located to the right of the dehumidifier setpoint, to set your  
desired humidity level for dehumidification in the summer.  
Inside  
Inside  
Humidity  
DEHUMIDIFIER  
%
DONE  
CANCEL  
M19967  
22-5211-02  
27  
69-1817—04  
NOTE: The dehumidification setpoint can range from 40% to 80% in 5% increments. The default  
dehumidification setpoint is 50%.  
3. Press Done key to save your changes and return to the Home Screen.  
4. Press Cancel key to return to Home Screen without saving any changes.  
Dehumidification Control  
If the dehumidification control has been enabled, the communicating Comfort Control attempts to  
control to this dehumidification setpoint by turning on the air conditioner. In extremely high humidity  
conditions, Comfort Control keeps the air conditioner running for up to 3°F below your temperature  
setpoint. It does this when trying to achieve your desired humidity setpoint and balance that with  
your temperature setpoint.  
NOTE: If auto changeover is selected, the deadband can be no closer than 5 degrees with  
dehumidification enabled.  
Trane Proprietary Humidity Control  
When enabled, this feature will disable any blower off delays and disable continuous fan mode when  
the indoor humidity is above the dehumidification setpoint. This will help prevent coil condensation  
from being evaporated back into the air stream.  
22-5211-02  
28  
69-1817—04  
 
href="
CONTROLLING YOUR INSIDE HUMIDIFICATION SETTING  
If the humidification control has been enabled, the communicating Comfort Control will read the  
inside humidity level and set a desired humidity level to help humidify the house.  
1. Press the More key until the inside humidity percent and humidification setpoint are shown.  
2. Use Up and Down arrow keys, located to the right of the humidification setpoint, to set your  
desired humidity level for humidification in the winter.  
Inside  
Inside  
Humidity  
HUMIDIFIER  
%
DONE  
CANCEL  
M19967  
22-5211-02  
29  
69-1817—04  
NOTE: The Humidification setpoint can range from 10% to 60% in 5% increments. The default  
humidification setpoint is 50%.  
3. Press Done key to save your changes and return to the Home screen.  
4. Press Cancel key to return to Home screen without saving any changes.  
Humidification Control  
If the humidification control has been enabled, the Comfort Control attempts to control to this  
humidification setpoint by turning on the humidifier.  
Frost Control  
TM  
If your ComfortLink II communicating system is equipped with an outdoor temperature sensor and  
a humidifier, you can use the frost control feature to control window condensation during the heating  
season. Frost control works by reducing humidification when conditions indicate that condensation  
or frost can occur.  
The degree of frost control is determined by the setting you choose between 0 and 10. Press More  
key until you come to the frost setting screen. The display shows FROST and a number from 0 to 10.  
When the factory setting (5) results in too much condensation or frost on the windows, lower the  
setting. When the air seems too dry, raise the setting.  
22-5211-02  
30  
69-1817—04  
Temperature Recovery  
Your Comfort Control comes with a feature called Adaptive Intelligent Recovery (AIR), which  
eliminates all guesswork when setting your schedule. How long does it take the furnace to warm  
your house in the morning before you get out of bed or how long does it take the air conditioner to  
cool your house in the afternoon before you return from work? No problem. The Comfort Control  
determines that for you.  
Simply set your program schedule to the time you want the house to be at your comfort temperature.  
The Comfort Control then turns on the heating or cooling at just the right time to have your home  
reach your scheduled temperature at your scheduled time.  
For example: you get out of bed at 6:00 AM and want the temperature to be 70°F (21.1°C). Set the  
0
Wake period for 6:00 AM and 70 F (21.1°C). The Comfort Control then turns on the heat before  
0
6:00 AM to raise the temperature to 70 F (21.1°C) by 6:00 AM.  
The Comfort Control alerts you that the heating or cooling system is coming on before a scheduled  
time by showing “Recovery” on the screen.  
22-5211-02  
31  
69-1817—04  
href="
TUE  
FAN  
Inside  
Set  
AUTO  
Following  
Schedule  
Recovery  
SYSTEM  
HEAT  
PM  
Humidity  
SCHED  
HOLD  
CLOCK SCREEN MORE  
M19968  
IMPORTANT  
It takes about a week for the Comfort Control to adjust to local weather, your schedule, the  
construction of your home and your heating and/or cooling system. Your Comfort Control  
learns from experience. Each day it checks how closely it reached the recovery time and  
adjusts the next day’s recovery start time accordingly.  
22-5211-02  
32  
69-1817—04  
href="
Advanced Heat Pump Features  
SET CURRENT DAY  
SET MONTH  
If you have a heat pump heating system, your Comfort Control  
can use some special features when used with an Outdoor  
Temperature Sensor, such as compressor and/or backup heat  
lockout based on outside temperature. For example, if your  
backup heat does not turn on above a designated outside  
temperature, your system uses an advanced heat pump  
feature.  
MMOONN  
TUE  
WED  
THU  
FRI  
SAT  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
CHANGE FILTER UV LAMP HUMIDIFIER PAD  
DONE  
Setting the Calendar  
This Comfort Control is designed to automatically keep current  
time and day in memory for up to ten years, under normal use,  
once the calendar is set. There are two ways to set the  
calendar for this Comfort Control:  
USE ARROWS TO SET YEAR AND TIME  
MMOONN  
WED  
THU  
FRI  
SAT  
SUN  
OK TO PICK MULTIPLE DAYS SCREEN LOCKED  
CHANGE FILTER UV LAMP HUMIDIFIER PAD  
SETTING CALENDAR AFTER COMFORT CONTROL IS ALREADY  
FUNCTIONING  
See steps 1 through 4, in “Advanced Settings” on page 34, to  
set year, month and day.  
PM  
DONE  
SETTING CALENDAR WHEN COMFORT CONTROL IS FIRST POWERED  
When this Comfort Control is first powered, the display is ready  
to set the calendar.  
M22645  
22-5211-02  
33  
69-1817—04  
href="
ADVANCED SETTINGS  
Your Comfort Control has many advanced settings to match your heating and cooling system. But  
you can change these settings to match your lifestyle:  
1. From the Home Screen, press the System key. Five blank touch keys show on the bottom of  
the screen between the Done and Cancel keys.  
2. Press and hold the center blank key for approximately five seconds, until the screen changes.  
TUE  
CHANGE FILTER UV LAMP HUMIDIFIER PAD  
Inside  
Set To  
Following  
Schedule  
SYSTEM  
EM HEAT  
OFF  
PM  
COOL  
DONE  
CANCEL  
M22653  
22-5211-02  
34  
69-1817—04  
 
href="
3. Release the center key when the display on your Comfort Control matches the display below.  
ADVANCE TO NEXT  
USER SETUP  
USER SETUP  
CURRENT  
SETTING  
NUMBER  
MON  
WED  
THU  
FRI  
SAT  
SUN  
DONE  
CHANGE THE  
CURRENT  
SETTING  
PRESS TO EXIT  
USER SETUP  
M22654  
22-5211-02  
35  
69-1817—04  
USER SETUP MENU  
Step 1. User Setup Number 0120: First Two Digits of Current Calendar  
Year  
To change current setting, press the Up or Down arrow key to the right of the two-digit number in the  
lower right corner of the screen. Options:  
20 - Equals years 20xx.  
21 - Equals years 21xx.  
To advance to the next Setup Number, press the Up arrow key to the right of 0120. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 2. User Setup Number 0130: Last Two Digits of Current Calendar  
Year  
To change Options, press the Up or Down arrow key to the right of the two-digit number in the lower  
right corner of the screen. Options:  
01 through 99 - equals years 2001 through 2099.  
To advance to the next Setup Number, press the Up arrow key to the right of 0130. To go back to the  
previous Setup Number, press the Down arrow key.  
22-5211-02  
36  
69-1817—04  
Step 3. User Setup Number 0140: Current Calendar Month  
To change Options, press the Up or Down arrow key to the right of number in lower right corner of  
the screen. Options:  
1 through 12 - equals January through December.  
To advance to the next Setup Number, press the Up arrow key to the right of 0140. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 4. User Setup Number 0150: Current Calendar Date  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
1 through 31 - equals 1st of a month to 31st of a month.  
To advance to the next Setup Number, press the Up arrow key to the right of 0150. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 5. User Setup Number 0160: Schedule Options  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
0 - Non-programmable. Comfort Control is non-programmable.  
4 - Programmable. Comfort Control is fully programmable, allowing all 7 days to be programmed.  
22-5211-02  
37  
69-1817—04  
To advance to the next Setup Number, press the Up arrow key to the right of 0160. To go back  
to the previous Setup Number, press the Down arrow key.  
Step 6. User Setup Number 0165: Restore Energy Star Schedule  
To reset the programmed heating and cooling schedule back to the default Energy Star program  
schedule, press the Up or Down arrow key to the right of the number in the lower right corner of the  
screen. Options:  
0 -No. Use current heating and cooling schedule.  
1 -Yes. Use default Energy Star program schedule.  
To advance to the next Setup Number, press the Up arrow key to the right of 0165. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 7. User Setup Number 0186: Continuous Fan Airflow  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
25 through 100 - equals 25% airflow to 100% in continuous fan mode.  
To advance to the next Setup Number, press the Up arrow key to the right of 0186. To go back to the  
previous Setup Number, press the Down arrow key.  
22-5211-02  
38  
69-1817—04  
Step 8. User Setup Number 0280: Continuous Backlight  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:|  
0 - No. Continuous backlight OFF.|  
1 - Yes. Continuous backlight ON. Backlight will dim to half brightness 45 seconds after last key  
press.  
To advance to the next Setup Number, press the Up arrow key to the right of 0280. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 9. User Setup Number 0320: Display Temperature Shown in °F or °C  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:|  
0 - Fahrenheit.  
1 - Celsius.  
To advance to the next Setup Number, press the Up arrow key to the right of 0320. To go back to the  
previous Setup Number, press the Down arrow key.  
22-5211-02  
39  
69-1817—04  
Step 10. User Setup Number 0330: Daylight Savings On or Off  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
0 - Off: No adjustment for Daylight Savings in Fall and Spring.  
1 - On: Time is automatically adjusted for Daylight Savings in Fall and Spring. (US 1987)  
2 - On: Time is automatically adjusted for Daylight Savings in Fall and Spring. (US 2007)  
3 - On: Time is automatically adjusted for Daylight Savings in Fall and Spring. (Europe)  
To advance to the next Setup Number, press the Up arrow key to the right of 0330. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 11. User Setup Number 0380: Indoor Dehumidification Control.  
To change Option, press the Up or Down arrow key to the right of the number in the lower right hand  
corner of the screen. Options:  
0 - No dehumidification control  
1 - Integrated Temperature and humidity control (Factory default)  
4 - Trane droop (RH setpoint)  
The dehumidification control attempts to control the indoor humidity to the user’s dehumidification  
setpoint by running the compressor. In extremely high humidity conditions, the Comfort Control  
keeps the compressor running for up to 3°F (-1.7°C) below the temperature setpoint. It does this  
while trying to achieve the desired dehumidification setpoint and balancing that with the temperature  
setpoint.  
22-5211-02  
40  
69-1817—04  
Trane Droop is a feature that cycles the compressor on to improve indoor comfort by removing  
moisture from the air. The Droop cycle is activated when the indoor humidity is above the user’s  
dehumidification setpoint.  
Step 12. User Setup Number 0383: Dehumidification Maximum Droop.  
To change Option, press the Up or Down arrow key to the right of the number in the lower right hand  
corner of the screen. Options:  
1 - 1° F (0.5° C)  
2 - 2° F (1.0° C)  
3 - 3° F (1.5° C)  
Maximum droop is the amount of temperature overshoot allowed while attempting to control indoor  
humidity.  
Step 13. User Setup Number 0500: Furnace Air Filter Timer 1  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
0 - Off. Furnace filter timer is off.  
1 - 10 fan run time days (about one month).  
2 - 30 fan run time days (about three months).  
3 - 60 fan run time days (about six months).  
4 - 90 fan run time days (about nine months).  
5 - 120 fan run time days (about one year).  
22-5211-02  
41  
69-1817—04  
6 - 180 fan run time days (about one year and six months).  
7 - 270 fan run time days (about two years).  
8 - 365 fan run time days (about three years).  
9 - 30 fan continuous time days (one month).  
10 - 60 fan continuous time days (two months).  
11 - 90 fan continuous time days (three months).  
12 - 120 fan continuous time days (four months).  
13 - 180 fan continuous time days (six months).  
14 - 365 fan continuous time days (one year).  
To advance to the next Setup Number, press the Up arrow key to the right of 0500. To go back  
to the previous Setup Number, press the Down arrow key.  
Step 14. User Setup Number 0501: Furnace Air Filter Timer 2  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
0 - Off. Furnace filter timer is off.  
1 - 10 fan run time days (about one month).  
2 - 30 fan run time days (about three months).  
3 - 60 fan run time days (about six months).  
4 - 90 fan run time days (about nine months).  
5 - 120 fan run time days (about one year).  
6 - 180 fan run time days (about one year and six months).  
22-5211-02  
69-1817—04  
42  
7 - 270 fan run time days (about two years).  
8 - 365 fan run time days (about three years).  
9 - 30 fan continuous days (one month).  
10 - 60 fan continuous days (two months).  
11 - 90 fan continuous days (three months).  
12 - 120 fan continuous days (four months).  
13 - 180 fan continuous days (six months).  
14 - 365 fan continuous days (one year).  
To advance to the next Setup Number, press the Up arrow key to the right of 0501. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 15. User Setup Number 0510: Humidifier Pad Timer  
To change Options, press the Up or Down arrow key to the right of the number in lower right corner  
of the screen. Options:  
0 - Off. Humidifier pad timer is off.  
1 - 90 continuous days; 30 run time days (3 months)  
2 - 180 continuous days; 60 run time days (6 months)  
|3 - 365 continuous days; 90 run time days (12 months)  
To advance to the next Setup Number, press the Up arrow key to the right of 0510. To go back to the  
previous Setup Number, press the Down arrow key.  
22-5211-02  
43  
69-1817—04  
Step 16. User Setup Number 0530: Adaptive Intelligent Recovery  
To change Options, press the Up or Down arrow key to the right of the number in lower right  
corner of the screen. Options:  
0 - Conventional recovery  
1 - Adaptive intelligent recovery  
To advance to the next Setup Number, press the Up arrow key to the right of 0530. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 17. User Setup Number 0540: Number of Schedule Periods  
Available to Program  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of screen. Options:  
2 - Two program periods available (Wake and Sleep).  
4 - Four program periods available (Wake, Leave, Return and Sleep).  
To advance to the next Setup Number, press the Up arrow key to the right of 0540. To go back to the  
previous Setup Number, press the Down arrow key.  
22-5211-02  
44  
69-1817—04  
Step 18. User Setup Number 0640: Clock Format  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
12 - 12 hour clock.  
24 - 24 hour clock.  
To advance to the next Setup Number, press the Up arrow key to the right of 0640. To go back to the  
previous Setup Number, press the Down arrow key.  
Step 19. User Setup Number 0670: Screen Lockout Function  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
0 - All keys are available. Screen is unlocked.|  
1 - Screen is partially locked. All key functions are locked except the Temperature Up and Down  
keys and the Cancel key. Enter Advanced Setup to unlock the screen.  
2 - Screen is fully locked. Enter Advanced Settings to unlock the screen.  
To advance to the next Setup Number, press the Up arrow key to the right of 0670. To go back to the  
previous Setup Number, press the Down arrow key.  
22-5211-02  
45  
69-1817—04  
Step 20. User Setup Number 0700: Temperature Display Offset  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
-3 - Offset temperature display by -3°F (-1.5°C).  
-2 - Offset temperature display by -2°F (-1.0°C).  
-1 - Offset temperature display by -1°F (-0.5°C).  
0 - Offset temperature display by 0°F (0°C).  
1 - Offset temperature display by 1°F (0.5°C).  
2 - Offset temperature display by 2°F (1.0°C).  
3 - Offset temperature display by 3°F (1.5°C).  
NOTE: Offsetting the temperature display affects both the display as well as the control.  
To advance to the next Setup Number, press the Up arrow key to the right of 0700. To go back  
to the previous Setup Number, press the Down arrow key.  
Step 21. User Setup Number 0701: Humidity Display Offset  
To change Options, press the Up or Down arrow key to the right of the number in the lower right  
corner of the screen. Options:  
-5 - Offset humidity display by -5%  
-4 - Offset humidity display by -4%  
-3 - Offset humidity display by -3%  
22-5211-02  
69-1817—04  
46  
-2 - Offset humidity display by -2%  
-1 - Offset humidity display by -1%  
0 - Offset humidity display by 0%  
1 - Offset humidity display by 1%  
2 - Offset humidity display by 2%  
3 - Offset humidity display by 3%  
4 - Offset humidity display by 4%  
5 - Offset humidity display by 5%  
NOTE: Offsetting the indoor humidity display affects both the display as well as the control.  
22-5211-02  
69-1817—04  
47  
Error Codes  
The Comfort Control can alert the homeowner and installer to problems with the HVAC equipment or  
Comfort Control by using error codes. When displaying an Error Code, the screen will display “Err”  
and a bright red light will appear in the top-right corner of the comfort control. Refer to the Alert Code  
Addendum (document number 18-HD32D2-1/69-2009) provided with comfort control, or contact  
your authorized Trane dealer.  
22-5211-02  
48  
69-1817—04  
Q: Some or all keys on the display do not work; why?  
A: Comfort Control screen is locked. See “Advanced Settings” on page 34 to unlock keys on the  
screen.  
Q: Comfort Control is asking for heating or cooling to come on (screen shows “Heat On” or “Cool  
On” in display) but there is no heating or cooling running.  
A: Call your local heating and/or cooling contractor to check your heating and/or cooling system.  
Q: Under the Fan on the screen, Auto and On or Auto and Circ are shown. What does this mean?  
A: The Fan is programmed for either On or Circulate. See “Fan Schedule” on page 19 for more  
information.  
Q: Why doesn’t the Comfort Control respond when I touch the keys?  
A: Check to determine if the screen is in the Locked or Clean mode. See “Screen Locked” on  
page 24 or “Cleaning Your Comfort Control Screen” on page 21.  
Q: The fan is set to On but is not running; why?  
A: The The Trane Proprietary Humidity Control disables continuous fan mode when the indoor  
humidity is above the dehumidification setpoint. See “Trane Proprietary Humidity Control” on  
page 28 for additional information.  
22-5211-02  
69-1817—04  
49  
LIMITED WARRANTY LOW VOLTAGE ROOM COMFORT  
CONTROLS (PARTS ONLY)  
This limited warranty is extended by the manufacturer to the original purchaser and to any succeeding owner of  
the real property to which the low voltage room comfort control is originally affixed and applies to products  
purchased and retained for use within the U.S.A. and Canada.  
The limited warranty period begins when the low voltage room comfort control installation is complete, verified by  
installer's invoice or similar document. If installation completion and start-up date cannot be verified by installer's  
invoice or similar document, limited warranty coverage begins six (6) months after the date of manufacture based  
on the low voltage room comfort control serial number.  
If any part of your low voltage room comfort control fails because of a manufacturing defect within five (5) years  
from the date the limited warranty period begins, Warrantor will furnish without charge a new low voltage room  
comfort control. Any local transportation, related service labor, and diagnosis calls, are not included.  
This limited warranty does not apply if the low voltage room comfort control was purchased direct (i.e. from  
internet websites or auctions) on an uninstalled basis. Additionally, this limited warranty will not apply unless the  
low voltage room comfort control is: (1) installed by a licensed or qualified HVAC technician, (2) applied and  
installed in accordance with the manufacturer's recommendations in its Installer's Guide, and (3) in compliance  
with all industry standards, national, state, and local codes.  
This limited warranty does not cover your low voltage room comfort control if it is damaged while in your  
possession; including, but not limited to (1) damage caused by unreasonable use of the low voltage room  
comfort control, (2) damage from failure to properly maintain the low voltage room comfort control as set forth in  
the Use and Care manual, (3) damage that is not considered a manufacturing defect, such as acts of God,  
22-5211-02  
50  
69-1817—04  
malfunctions or failures resulting from fire, water, storms, lightning, earthquake, theft, riot, misuse, abuse,  
increased utility usage costs, or (4) performance problems due to improper selection / equipment match-up,  
installation, or application.  
THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER  
WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLEGENCE, EXPRESSED OR  
IMPLIED, IN LAW OF IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS  
FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR  
CONSEQUENTIAL DAMAGES.  
Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or  
limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This  
limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
Parts will be provided by our factory organization through an authorized service organization in your area listed in  
the yellow pages. If you wish further help or information concerning this limited warranty, contact:  
Residential Systems  
6200 Troup Highway  
Tyler, TX 75707  
Attention: Consumer Relations  
TW-1019-3308  
22-5211-02  
51  
69-1817—04  
href="
This comfort control contains a Lithium battery  
which may contain Perchlorate material. Due to  
State Law in California, the following statement  
is required:  
CUSTOMER ASSISTANCE  
If, after reading this guide, you have any  
questions concerning the operation of your  
Comfort Control, please call the Comfort  
Control Customer Assistance Helpline at 1-800-  
500-2041.  
Perchlorate Material - special handling may  
apply.  
perchlorate  
For service, contact your local heating and  
cooling contractor or visit  
Trane  
A business of American Standard Companies  
6200 Troup Highway  
Tyler, TX 75707  
® U.S. Registered Trademark  
Copyright © 2008 American Standard Inc.  
All Rights Reserved  
American Standard Inc.  
Troup Highway  
Pub. No. 22-5211-02  
69-1817—04 M.S. Rev. 11-08  
Printed in Mexico  
Tyler, TX 75711-9010