Home

href="
F61 Series  
Adaptor Plate Assembly  
INSTALLATION INSTRUCTIONS  
WHITE-RODGERS  
Operator: Save these instructions for future use!  
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY  
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE  
PERSONAL INJURY AND/OR PROPERTY DAMAGE.  
DESCRIPTION  
This adaptor plate assembly is designed for mounting a  
1F6X, 1F7X, or 1F9X series thermostat to the wall or to a  
junction box. The wall cover plate covers the junction box,  
wall damage, or old thermostat markings. The adaptor  
plateisdesignedtoallowhorizontalthermostatmounting,  
regardless of junction box orientation.  
Adaptor Plate  
5
” Phillips  
16  
All kits may not have adaptor plate or all screws shown.  
No. 6 X  
pan-head screw (2)  
3
” Phillips  
8
6-19 X  
pan-head screw (3)  
3
” flat-head  
4
Wall Cover  
Plate  
6-32 X  
machine screw (4)  
PRECAUTIONS  
CAUTION  
NOTE  
!
To prevent electrical shock and/or equip-  
ment damage, disconnect electrical power  
at main fuse or circuit breaker until installa-  
tion is complete.  
This instruction sheet is not intended as a wiring guide.  
Refer to the thermostat installation instructions to ensure  
proper wiring.  
CONTENTS  
Description ......................................................... 1  
Precautions ........................................................ 1  
Installation.......................................................... 2  
For 1F9X Digital Thermostats  
For 1F7X Quartz Clock Thermostats  
For 1F6X Thermostats  
WHITE-RODGERS DIVISION  
EMERSON ELECTRIC CO.  
9797 REAVIS ROAD  
PART NO. 37-5148B  
Printed in U.S.A.  
Replaces 37-5148A  
9607  
ST. LOUIS, MISSOURI 63123-5398  
href="
INSTALLATION  
FOR 1F9X DIGITAL THERMOSTATS  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Junction Box  
5
No. 6 X  
⁄ ” Phillips  
16  
pan-head screws  
Wall Cover Plate  
Thermostat Subbase  
(may have 2, 3, or  
4 mounting holes)  
Thermostat  
Figure 1. Mounting 1F9X digital thermostat to horizontal junction box  
Locate and drill two  
clearance holes in wall  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
⁄ ” Phillips  
16  
Junction Box  
Adaptor Plate  
5
No. 6 X  
pan-head screws  
Wall Cover Plate  
Thermostat Subbase  
(may have 2, 3, or  
4 mounting holes)  
Thermostat  
Figure 2. Mounting 1F9X digital thermostat to vertical junction box  
2
href="
NOTE  
When installing wall cover plate and thermostat directly to  
wall, usethepointedscrewssuppliedwiththethermostat.  
No. 6 X 1” pan-head screws  
(supplied with thermostat)  
Wall  
Wall Cover Plate  
Thermostat Subbase  
Thermostat  
Figure 3. Mounting 1F9X digital thermostat to wall  
FOR 1F7X QUARTZ CLOCK THERMOSTATS  
NOTE  
Do not install the wall mounting plate and subbase at the  
sametime.Thethermostatwillnotoperateproperlyifboth  
wall mounting plate and subbase are installed.  
FAN  
ON  
AUTO  
3
6-32 X ⁄ ” flat-head  
4
Junction Box  
SYSTEM  
COOL  
OFF  
machine screws  
HEAT  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Thermostat  
Subbase*  
Wall Cover Plate  
1
2
9
3
DA  
Y
6
50  
6
60  
3
70  
80  
90  
9
2
1
*Do not use both subbase and wall  
mounting plate – see note, above.  
90  
HI  
80  
70  
Wall Mounting  
Plate*  
LO  
60  
50  
Thermostat  
Figure 4. Mounting 1F7X quartz clock thermostat to horizontal junction box  
3
href="
NOTE  
Locate and drill two  
clearance holes in wall  
Do not install the wall mounting plate and subbase at the  
sametime.Thethermostatwillnotoperateproperlyifboth  
wall mounting plate and subbase are installed.  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Junction Box  
FAN  
ON  
AUTO  
3
6-32 X ⁄ ” flat-head  
4
SYSTEM  
COOL  
machine screws  
OFF  
Adaptor Plate  
HEAT  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Thermostat  
Subbase*  
Wall Cover Plate  
1
2
9
3
DA  
Y
6
50  
6
60  
3
70  
80  
90  
9
2
1
*Do not use both subbase and wall  
mounting plate – see note, above.  
90  
HI  
80  
70  
Wall Mounting  
Plate*  
LO  
60  
50  
Thermostat  
Figure 5. Mounting 1F7X quartz clock thermostat to vertical junction box  
NOTE  
NOTE  
Do not install the wall mounting plate and subbase at the When installing wall cover plate and thermostat directly to  
sametime.Thethermostatwillnotoperateproperlyifboth wall, usethepointedscrewssuppliedwiththethermostat.  
wall mounting plate and subbase are installed.  
FAN  
ON  
AUTO  
SYSTEM  
COOL  
No. 6 X 1” pan-head screws  
(supplied with thermostat)  
OFF  
HEAT  
Wall  
No. 6 X 1” pan-head screws  
(supplied with thermostat)  
Wall Cover Plate  
Thermostat  
Subbase*  
1
2
9
3
DA  
Y
6
50  
6
60  
3
70  
9
2
1
80  
90  
*Do not use both subbase and wall  
mounting plate – see note, above.  
90  
80  
70  
60  
50  
HI  
Wall Mounting  
Plate*  
LO  
Thermostat  
Figure 6. Mounting 1F7X quartz clock thermostat to wall  
4
href="
FOR 1F6X THERMOSTATS  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Junction Box  
3
No. 6 X ⁄ ” Phillips  
8
pan-head screws  
Instructions Inside Cover  
Wall Cover Plate  
Thermostat  
Thermostat Cover  
Figure 7. Mounting 1F60 thermostat to horizontal junction box  
Locate and drill two  
clearance holes in wall  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Junction Box  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Adaptor Plate  
3
No. 6 X ⁄ ” Phillips  
8
pan-head screws  
TIME  
SET  
SET  
BACK  
COOL OHEAT  
Wall Cover Plate  
0
0
3
5
6 9  
10 15  
°
C
F
°
AUTO CONT.  
FAN  
Thermostat  
Thermostat Cover  
Figure 8. Mounting 1F60 thermostat to vertical junction box  
5
href="
NOTE  
When installing wall cover plate and thermostat directly to  
wall, usethepointedscrewssuppliedwiththethermostat.  
No. 6 X 1” pan-head screws  
(supplied with thermostat)  
3
No. 6 X ⁄ ” Phillips  
8
pan-head screws  
Wall  
AM  
PM  
SETBACK  
Instructions Inside Cover  
TIME  
SET  
HEAT  
COOL  
SET  
BACK  
COOL OHEAT  
Wall Cover Plate  
0
0
3
5
6 9  
10 15  
WHIT-RODGERS  
°
C
F
°
AUTO CONT.  
FAN  
50  
60 70 80 90  
°
F
32  
10  
21  
°
C
Thermostat  
Thermostat Cover  
Figure 9. Mounting 1F60 thermostat to wall  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
Junction Box  
3
No. 6 X ⁄ ” Phillips  
8
pan-head screws  
Wall Cover Plate  
CLEAR  
SET  
BACK  
AM  
PM  
TIME  
SET  
SETBACK  
HEAT  
Instructions Inside Cover  
COOL OFF HAT EMHT  
Thermostat Subbase  
COMPRESSOR  
MALFUNCTION  
COOL  
EMERGENCY  
HEAT  
0
0
3
5
6 9  
10 15  
°
C
F
AUXILIARY  
HEAT  
°
AUTO CONT.  
FAN  
60  
65  
WHITRODGERS  
70 21  
75  
55  
Thermostat  
(connect harness –  
snap onto subbase)  
80  
10 50  
85  
90 32  
°
F
°
C
Thermostat Cover  
Figure 10. Mounting 1F62 thermostat to horizontal junction box  
6
href="
Locate and drill two  
clearance holes in wall  
3
6-32 X ⁄ ” flat-head  
4
machine screws  
3
6-32 X ⁄ ” flat-head  
4
Junction Box  
Adaptor Plate  
machine screws  
3
No. 6 X ⁄ ” Phillips  
8
pan-head screws  
Wall Cover Plate  
CLEAR  
SET  
BACK  
AM  
PM  
TIME  
SET  
SETBACK  
HEAT  
Instructions Inside Cover  
COOL OFF HAT EMHT  
Thermostat  
Subbase  
COMPRESSOR  
MALFUNCTION  
COOL  
EMERGENCY  
HEAT  
0
0
3
5
6 9  
10 15  
°
C
F
AUXILIARY  
HEAT  
°
AUTO CONT.  
FAN  
60  
65  
WHIT-RODGERS  
70 21  
75  
55  
Thermostat  
(connect harness –  
snap onto subbase)  
80  
10 50  
85  
90 32  
°
F
°
C
Thermostat Cover  
Figure 11. Mounting 1F62 thermostat to vertical junction box  
NOTE  
When installing wall cover plate and thermostat directly to  
wall, usethepointedscrewssuppliedwiththethermostat.  
No. 6 X 1” pan-head screws  
(supplied with thermostat)  
3
No. 6 X ⁄ ” Phillips  
8
pan-head screws  
Wall  
Wall Cover Plate  
CLEAR  
SET  
BACK  
AM  
PM  
TIME  
SET  
SETBACK  
HEAT  
Instructions Inside Cover  
COOL OFF HAT EMHT  
Thermostat  
Subbase  
COMPRESSOR  
MALFUNCTION  
COOL  
EMERGENCY  
HEAT  
0
0
3
5
6 9  
10 15  
°
C
F
AUXILIARY  
HEAT  
°
AUTO CONT.  
FAN  
60  
65  
WHIT-RODGERS  
70 21  
75  
55  
Thermostat  
(connect harness –  
snap onto subbase)  
80  
10 50  
85  
90 32  
°
F
°
C
Thermostat Cover  
Figure 12. Mounting 1F62 thermostat to wall  
7
If you need further information about this product, please write to  
White-Rodgers Division, Emerson Electric Co.  
9797 Reavis Road  
St. Louis, MO 63123-5398  
Attention: Technical Service Department